Gas Appliance Installation and Inspection L3P3,U11,LO3,AC3.7.

Gas Appliance Installation and Inspection L3P3,U11,LO3,AC3.7.

Professional Development

6 Qs

quiz-placeholder

Similar activities

ACS Quiz 2

ACS Quiz 2

Professional Development

11 Qs

Phase4mod1 Legislation

Phase4mod1 Legislation

Professional Development

10 Qs

Phase4.mod13.chimney test

Phase4.mod13.chimney test

Professional Development

7 Qs

Dentepro Fluoride Free Toothpaste #fluorideawarenessweek

Dentepro Fluoride Free Toothpaste #fluorideawarenessweek

University - Professional Development

8 Qs

Chimneys and Flues Quiz

Chimneys and Flues Quiz

Professional Development

9 Qs

Phase4,Mod15 re-establish

Phase4,Mod15 re-establish

Professional Development

5 Qs

Tissue Viability

Tissue Viability

Professional Development

11 Qs

phase4.mod14.flue config.

phase4.mod14.flue config.

Professional Development

6 Qs

Gas Appliance Installation and Inspection L3P3,U11,LO3,AC3.7.

Gas Appliance Installation and Inspection L3P3,U11,LO3,AC3.7.

Assessment

Quiz

Science

Professional Development

Hard

Created by

Craig Boothright

Used 2+ times

FREE Resource

6 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be installed at the terminal of a gas appliance flue according to BS5440pt1?

Catchment space

Restrictors

Dampers

Chimney pot

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of a flue flow test?

To detect concentrations of CO, CO2, oxygen, and nitrogen

To check for adequate air supply

To investigate signs of staining and discolouration

To confirm products of combustion are traveling up the flue

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What does a successful spillage test confirm?

The products of combustion are not being ejected into the room

The flue is not affected by extractor fans or cooker hoods

The smoke from the match is drawn into the flue

The appliance is operating at maximum efficiency

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of using a flue gas analyser on gas appliances?

To check for adequate air supply

To investigate signs of staining and discolouration

To confirm the presence of a catchment space

To detect concentrations of CO, CO2, oxygen, and nitrogen

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be completely free of debris and sealed from the surrounding structure for a gas fire installation?

Restrictors

Chimney pot

Dampers

Catchment space

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be permanently removed or fastened to be permanently open for a gas fire installation on the chimney?

Chimney pot

Restrictors

Catchment space

Dampers