Calibration and Maintenance of Weighing Balance Quiz

Authored by Delphine C.

Science

12th Grade

Used 3+ times

Calibration and Maintenance of Weighing Balance Quiz
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What is the purpose of calibration in the context of weighing balance?

To adjust the balance pan

To clean the balance

To replace instrument parts

To compare the accuracy of measurements with known standards

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What is the tolerance range in the context of weighing balance calibration?

The permitted deviation between standard weight and scale reading

The range of weights that can be measured

The temperature range for calibration

The time interval for calibration

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What type of weights should be used for calibration of weighing balance?

NIST Class A weights

NIST Class S weights

NIST Class C weights

NIST Class B weights

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What is the purpose of the Repeatability Test in the context of weighing balance verification?

To determine the repeatability of the scale used

To test for errors in weighing scale

To test the sensitivity of the balance

To determine the minimum weight change that the weighing device can detect

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What does the Eccentricity Test determine in the context of weighing balance verification?

The permitted deviation between standard weight and scale reading

How the reading is affected when test load is placed at different locations of the weighing pan

The minimum weight change that the weighing device can detect

The repeatability of the scale used

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What should be done before performing a test with a weighing balance to minimize errors?

Place chemicals directly onto the pan

Clean the balance pan with bare hands

Drop objects onto the weighing pan

Acclimatize the test weight to the ambient temperature of the balance

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

What is the purpose of keeping the sliding door of the chamber fully closed when using an analytical balance?

To avoid air currents and minimize vibration or huge temperature difference inside vs. outside the housing chamber

To increase air currents and minimize vibration

To allow temperature difference inside vs. outside the housing chamber

To avoid vibration and temperature difference inside vs. outside the housing chamber

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Microsoft

Continue with Microsoft

or continue with

Facebook

Facebook

Apple

Apple

Others

Others

Already have an account?