Voltage Drop Calculations Quiz

Voltage Drop Calculations Quiz

Professional Development

15 Qs

quiz-placeholder

Similar activities

6th Period Choice Board

6th Period Choice Board

KG - Professional Development

10 Qs

Physics Quiz 2

Physics Quiz 2

Professional Development

11 Qs

Parcial campo magnético

Parcial campo magnético

Professional Development

13 Qs

4 acteurs du choc électrique (H-Q)

4 acteurs du choc électrique (H-Q)

Professional Development

10 Qs

Electricity- Vocabulary

Electricity- Vocabulary

Professional Development

10 Qs

Special Locations in Electrical Installations Quiz

Special Locations in Electrical Installations Quiz

Professional Development

15 Qs

Circuitos electricos

Circuitos electricos

Professional Development

20 Qs

M3.09 Capacitance/Capacitor Cat B

M3.09 Capacitance/Capacitor Cat B

Professional Development

16 Qs

Voltage Drop Calculations Quiz

Voltage Drop Calculations Quiz

Assessment

Quiz

Physics

Professional Development

Medium

Created by

Dean Kirby

Used 1+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum permitted voltage drop for a lighting circuit according to table 4ab in the wiring regulations?

6.9 volts

10.5 volts

8.2 volts

4.5 volts

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the actual volts drop for a 3 kilowatt water heater wired in 2.5 millimeter twin earth cable with a circuit length of 44 meters?

14.1 volts

12.6 volts

8.7 volts

10.3 volts

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum length of a one millimeter twin and earth cable for a lighting circuit to not exceed the maximum permitted volts drop of 6.9 volts?

32.5 meters

39.2 meters

42.8 meters

47.6 meters

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum length of a six millimeter twin and earth cable for a 7 kilowatt cooker to not exceed the maximum permitted volts drop of 11.5 volts?

45.3 meters

51.8 meters

58.2 meters

63.7 meters

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the mvam number for 2.5 millimeter twin earth cable according to table 4d5 in the wiring regulations?

22

25

18

15

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the design current for a 230 volt, 7 kilowatt cooker?

30.4 amps

33.7 amps

28.6 amps

25.3 amps

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum permitted voltage drop for a non-lighting circuit according to table 4ab in the wiring regulations?

5.2 volts

6.9 volts

8.5 volts

11.5 volts

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?