Conductor Installations Quiz

Conductor Installations Quiz

11th Grade

20 Qs

quiz-placeholder

Similar activities

dichtheid HV2

dichtheid HV2

10th - 11th Grade

18 Qs

Quiz # 2

Quiz # 2

11th Grade

20 Qs

[Reviewer] T3 WW2: Work, Power and Energy

[Reviewer] T3 WW2: Work, Power and Energy

10th Grade - University

16 Qs

Friction Quiz

Friction Quiz

11th - 12th Grade

20 Qs

3/25 Circuits

3/25 Circuits

11th - 12th Grade

17 Qs

Energy Vocabulary (ESL)

Energy Vocabulary (ESL)

9th - 12th Grade

19 Qs

Forces Test Review

Forces Test Review

7th - 12th Grade

17 Qs

P4. Radioactivity

P4. Radioactivity

8th - 12th Grade

20 Qs

Conductor Installations Quiz

Conductor Installations Quiz

Assessment

Quiz

Physics

11th Grade

Easy

Created by

TIMOTHY COLVIN

Used 1+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the total pulling tension when pulling a cable weighing 5 pounds per foot through a 500' conduit with a coefficient of friction of 0.35?

176.75

180

875

7,142

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In general, the pull exerted on cables pulled through cable trays using a basket grip not attached to the conductor should not exceed _____.

500 pounds

1,000 pounds

2,500 pounds

6,000 pounds

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In general, the sidewall load on any raceway run should not exceed _____.

100 pounds

500 pounds

350 pounds

200 pounds

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum length of cable weighing 5 lbs/ft that can be pulled through a 45-degree bend with a coefficient of friction of 1.48 using equipment with a maximum pulling force of 2,000 pounds?

40

270

308

1,351

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A typical hand-crank wire puller, using 30 pounds of force, can pull up to _____.

300 pounds

800 pounds

1,500 pounds

4,000 pounds

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When pulling cable with a capstan, what is the maximum pulling speed that should utilized?

10 feet per minute

20 feet per minute

40 feet per minute

75 feet per minute

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The preferred method for checking for damaged conduit before pulling cable is _____.

a visual inspection of the conduit

using a vacuum powered fishing system

using a conduit swab to clear debris

performing a test pull

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?