What is initial verification according to the regulations?

Electrical Inspection and Testing Quiz

Quiz
•
Other
•
Professional Development
•
Hard
Dean Kirby
Used 2+ times
FREE Resource
15 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The final inspection and test on a new installation or a new circuit
The inspection and test of an installation after being put into service
The inspection and test of an installation before being put into service
The inspection and test of an existing installation or circuit
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What should be done on completion of the verification according to the regulations?
Prepare a quotation for the customer
Prepare a list of defects for the customer
Prepare a certificate for the customer
Prepare a report for the customer
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following is not a check that is carried out during initial verification of an installation?
That the installed electrical equipment is not damaged or defective
Presence of fire barriers
Connection of conductors
Prevention of mutual detrimental influences
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the correct sequence of testing for an installation according to the regulations?
Earth fault loop impedance, polarity, insulation resistance, continuity of conductors
Insulation resistance, continuity of conductors, earth fault loop impedance, polarity
Continuity of conductors, insulation resistance, polarity, earth fault loop impedance
Polarity, insulation resistance, continuity of conductors, earth fault loop impedance
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the minimum insulation resistance reading for a new installation according to the regulations?
10 mega ohms
1 mega ohm
100 kilo ohms
100 mega ohms
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of periodic testing according to the regulations?
To verify the installation before being put into service
To advise the client that installations to previous editions of regulations are unsafe
To inspect and test any circuit or installation that is not new
To identify installation defects
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What must an inspector not do according to the regulations?
Partially dismantle an installation in order to carry out an inspection and test
Identify installation defects
Advise the client that installations to previous editions of regulations are unsafe
Work on a dead circuit
Create a free account and access millions of resources
Similar Resources on Quizizz
10 questions
S Plan Plus wiring

Quiz
•
Professional Development
17 questions
Solid Fuel Fires

Quiz
•
Professional Development
13 questions
PP1 Hot Water Systems Quiz

Quiz
•
Professional Development
18 questions
ISTQB 1

Quiz
•
Professional Development
10 questions
PPE Inspection Quiz

Quiz
•
Professional Development
20 questions
ICPE

Quiz
•
Professional Development
10 questions
Unit 101: Structure of the construction industry 3

Quiz
•
Professional Development
10 questions
Sanitation System Quiz PPT1

Quiz
•
Professional Development
Popular Resources on Quizizz
15 questions
Character Analysis

Quiz
•
4th Grade
17 questions
Chapter 12 - Doing the Right Thing

Quiz
•
9th - 12th Grade
10 questions
American Flag

Quiz
•
1st - 2nd Grade
20 questions
Reading Comprehension

Quiz
•
5th Grade
30 questions
Linear Inequalities

Quiz
•
9th - 12th Grade
20 questions
Types of Credit

Quiz
•
9th - 12th Grade
18 questions
Full S.T.E.A.M. Ahead Summer Academy Pre-Test 24-25

Quiz
•
5th Grade
14 questions
Misplaced and Dangling Modifiers

Quiz
•
6th - 8th Grade