Electrical Inspection and Testing Quiz

Electrical Inspection and Testing Quiz

Professional Development

15 Qs

quiz-placeholder

Similar activities

PP1 Hot Water Systems Quiz

PP1 Hot Water Systems Quiz

Professional Development

13 Qs

ISTQB 1

ISTQB 1

Professional Development

18 Qs

Advanced Class Chapter 4

Advanced Class Chapter 4

Professional Development

10 Qs

INTRODUCTION TO METROLOGY

INTRODUCTION TO METROLOGY

Professional Development

13 Qs

BS7671 Part 3

BS7671 Part 3

Professional Development

10 Qs

18th edition part 3 mock 1

18th edition part 3 mock 1

Professional Development

10 Qs

Sanitation System Quiz PT1

Sanitation System Quiz PT1

Professional Development

10 Qs

18th Edition Part 6 Mock 2

18th Edition Part 6 Mock 2

Professional Development

10 Qs

Electrical Inspection and Testing Quiz

Electrical Inspection and Testing Quiz

Assessment

Quiz

Other

Professional Development

Hard

Created by

Dean Kirby

Used 2+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is initial verification according to the regulations?

The final inspection and test on a new installation or a new circuit

The inspection and test of an installation after being put into service

The inspection and test of an installation before being put into service

The inspection and test of an existing installation or circuit

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What should be done on completion of the verification according to the regulations?

Prepare a quotation for the customer

Prepare a list of defects for the customer

Prepare a certificate for the customer

Prepare a report for the customer

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is not a check that is carried out during initial verification of an installation?

That the installed electrical equipment is not damaged or defective

Presence of fire barriers

Connection of conductors

Prevention of mutual detrimental influences

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the correct sequence of testing for an installation according to the regulations?

Earth fault loop impedance, polarity, insulation resistance, continuity of conductors

Insulation resistance, continuity of conductors, earth fault loop impedance, polarity

Continuity of conductors, insulation resistance, polarity, earth fault loop impedance

Polarity, insulation resistance, continuity of conductors, earth fault loop impedance

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum insulation resistance reading for a new installation according to the regulations?

10 mega ohms

1 mega ohm

100 kilo ohms

100 mega ohms

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of periodic testing according to the regulations?

To verify the installation before being put into service

To advise the client that installations to previous editions of regulations are unsafe

To inspect and test any circuit or installation that is not new

To identify installation defects

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What must an inspector not do according to the regulations?

Partially dismantle an installation in order to carry out an inspection and test

Identify installation defects

Advise the client that installations to previous editions of regulations are unsafe

Work on a dead circuit

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?