Search Header Logo

175 - 210

Authored by pgfyi fernandobrasil@p2e.com.br

Social Studies

Professional Development

Used 2+ times

175 - 210
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

35 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where stadiums, arenas and grandstands have a minimum of _______________ fixed seats and provide audible public announcements, pre-recorded or real-time captions of those audible public announcements shall be provided.

3,000

5,000

10, 000

15, 000

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An approved audible device, located on the exterior of the building in an approved location, must be connected to each______________________903.4.2

emergency evacuation system

emergency lighting system

exit alarm system

automatic sprinkler system

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

41 Areas of refuge must be provided with ______________________________________ complying with the code.

a clear hallway 66 inch minimum in width

a two-way communication system

a emergency first aid station

a fire extinguishing tools cabinet

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

At least one ambulatory-accessible water closet compartment is required in a toilet room where the total number of water closet compartments and urinals provided in the room is a minimum of _______________ fixtures.

4

6

10

12

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A self-storage facility containing 160 storage spaces shall be provided with a minimum of _______________ accessible individual self-storage spaces.

one

two

five

eight

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A high-rise building is defined as a building having occupied floors located more than _______________ feet above the lowest level of fire department vehicle access.

55

75

120

160

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a high-rise building, if standby power is a generator within the building, it shall be located in a separate room enclosed by minimum _______________ fire-resistance-rated assemblies or horizontal assemblies, or both.

1-hour fire barrier

1 hour fire-partition

2-hour fire wall

2-hour fire barrier

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?