MULTIPLE CHOICE QUESTION
30 sec • 1 pt
In buildings constructed in accordance with the provisions of conventional light-frame construction bearing partitions perpendicular to joists may not be offset from supporting girders, walls or partitions ___________________ unless such joists are of sufficient size to carry the additional load.
12 inches
24 inches
more than twice the joist depth
more than the joist depth
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A poured concrete basement wall is 7 feet high and 7.5 inches thick. The lateral backfill soil load is 60 psf. The unbalance backfill height is 7 feet. What is the required re-bar size and spacing?
#6 at 48"
#7 at 39"
#7 at 60"
Plain Concrete no re-bar required
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
For the purpose of required natural lighting, any room is permitted to be considered as a portion of an adjoining room where _______ of the area of the common wall is open and unobstructed and provides an opening of not less than one-tenth of the floor area of the interior room or 25 square feet, whichever is greater. Exceptions ignored.
one-half
one-third
one-quarter
one-tenth
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A plain masonry basement wall is 7 feet high . The lateral backfill soil load is 60 psf. The unbalance backfill height is 7 feet. What is the minimum required wall thickness and the type of wall required.
8" Hollow
10 Hollow
10" Solid
8" Solid
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the allowable area of a Group F-2 single story building of Type IIIB Construction equipped throughout with an automatic sprinkler
18,000 square feet
18,000 square feet
36,000 square feet
72,000 square feet
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
In buildings constructed in accordance with the provisions of conventional light-frame construction trimmer and header joists must be doubled, or of lumber of equivalent cross section, where the span of the header exceeds ______________.
4 feet
5 feet
6 feet
7 feet
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A wall designed to resist lateral forces parallel to the plane of a wall.
Braced wall
Cripple wall
Vertical wall
Shearwall
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?
Similar Resources on Wayground
16 questions
Resources and Development Part 1
Quiz
•
10th Grade - Professi...
15 questions
GE USELF Chapter 1
Quiz
•
University - Professi...
15 questions
GK Marathon -01 Quiz
Quiz
•
10th Grade - Professi...
17 questions
18th Century Political Formations
Quiz
•
7th Grade - Professio...
18 questions
Sectors of Indian Economy Part 3
Quiz
•
10th Grade - Professi...
10 questions
Obstacles in Sustainable Development
Quiz
•
University - Professi...
10 questions
mass media and communication
Quiz
•
KG - Professional Dev...
11 questions
4 I's Review
Quiz
•
7th Grade - Professio...
Popular Resources on Wayground
8 questions
2 Step Word Problems
Quiz
•
KG - University
20 questions
Comparing Fractions
Quiz
•
4th Grade
15 questions
Fractions on a Number Line
Quiz
•
3rd Grade
20 questions
Equivalent Fractions
Quiz
•
3rd Grade
25 questions
Multiplication Facts
Quiz
•
5th Grade
10 questions
Latin Bases claus(clois,clos, clud, clus) and ped
Quiz
•
6th - 8th Grade
22 questions
fractions
Quiz
•
3rd Grade
7 questions
The Story of Books
Quiz
•
6th - 8th Grade