QUIZ WOW 1

QUIZ WOW 1

Professional Development

25 Qs

quiz-placeholder

Similar activities

Deployment Quiz -Compliance

Deployment Quiz -Compliance

Professional Development

20 Qs

plumbing question revision

plumbing question revision

Professional Development

23 Qs

L3 YR2 Revision 3 (Cold 3)

L3 YR2 Revision 3 (Cold 3)

Professional Development

20 Qs

Compressor

Compressor

Professional Development

21 Qs

Premium test

Premium test

Professional Development

20 Qs

SUPREME WITH VEGGIES FOR MNGRS CL

SUPREME WITH VEGGIES FOR MNGRS CL

Professional Development

20 Qs

Chapter 6 Study Guide: The Cardiovascular System

Chapter 6 Study Guide: The Cardiovascular System

Professional Development

26 Qs

POM: Process Sampels

POM: Process Sampels

12th Grade - Professional Development

20 Qs

QUIZ WOW 1

QUIZ WOW 1

Assessment

Quiz

Other

Professional Development

Medium

Created by

Amirul MM

Used 13+ times

FREE Resource

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Gate valve is type of valve that is used on christmastree to adjust flow of fluid from well.

True

False

Answer explanation

Gate valve for fully isolated

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

PSDV is closed in case of process emergency shutdown condition.

True

False

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

ESDV has delay time 30 second to close after shut down case initiated.

True

False

Answer explanation

ESDV panel don't have delay time facility, directly close after SD system is active

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

SDV stroking test has to be done during process shut down only.

True

False

Answer explanation

stroking test facility can be used, no need SD

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

All ESDV will be closed due to SD 2 on platform.

True

False

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

To prevent back flow, check valve is installed on just right after trunkline ESDV.

True

False

Answer explanation

no check valve, connection on sea line after battery limit (ESDV) is not allowed

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Production manifold PSV replacement has to be done by shut in the well and depressurize the manifold.

True

False

Answer explanation

no PSV on manifold