NEC code look up 2

NEC code look up 2

Professional Development

10 Qs

quiz-placeholder

Similar activities

18th Edition Wiring Regulations Quiz

18th Edition Wiring Regulations Quiz

Professional Development

15 Qs

M3.3 Electrical Terminology cat B

M3.3 Electrical Terminology cat B

Professional Development

8 Qs

CRO DSO

CRO DSO

Professional Development

9 Qs

TRANSFORMER

TRANSFORMER

Professional Development

10 Qs

F022

F022

Professional Development

8 Qs

Block 2 - 5A - Synchro and Servos

Block 2 - 5A - Synchro and Servos

Professional Development

15 Qs

Voltage Drop Calculations Quiz

Voltage Drop Calculations Quiz

Professional Development

15 Qs

Transformer Working and Construction Quiz

Transformer Working and Construction Quiz

Professional Development

8 Qs

NEC code look up 2

NEC code look up 2

Assessment

Quiz

Physics

Professional Development

Hard

Created by

Barry Bond

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Switches are generally wired so that all switching occurs in which conductor?

Bonding jumper

Grounded

Ungrounded

Neutral

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How many general purpose lighting and receptacle breakers will be required on a 2500 sq foot home? You can only use 15 amp breakers.

2

3

4

5

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electrical equipment room is located in the area near the bathroom of a school. What is allowed to be stored inside the equipment room?

Dry goods

Nothing

Cleaning chemicals

Mop buckets and brooms

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Conductors shall be permitted to be connected in parallel for service conductor wiring (electrically joined) as long as they are not smaller than _________?

2 AWG

1 AWG

1/0 AWG

2/0 AWG and larger

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Blood borne pathogen training is required

every 6 years

monthly

annually

only once

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a dwelling unit if the laundry and the bathroom are in the same room what is the minimum branch circuits that will be required?

1

2

3

4

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What is the wiring configuration of this transformer?

See/Saw

Delta/Delta

Delta/Wye

Delta/Star