1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
01: Conditioned air is distributed to:
A: Cockpit, cargo bays and cabin
B: Cockpit, fwd and aft cabins
C: Cockpit, avionics bay and cabin
D: Cockpit, cabin and holds 1 and 2 only
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
02: Hot air fault light illuminates on the air conditioning panel
A: The hot air press. reg. valve opens and the trim air valves close.
B: The hot air press. reg. valve closes and the trim air valves open.
C: The hot air press. reg. valve closes and the trim air valves close.
D: The hot air press. reg. valve opens and the trim air valves open.
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
3:Does the trim air provide the warm air or the cold air to the air conditioning system?
A: Cold air
B: Warm air
C : normal air
D : none
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
4: In case of zone controller primary and secondary channel failure, what temperatures are maintained by pack one and pack two?
A: 15 deg.C both
B: 25 deg.C both
C: 20 deg.C for pack one and 10 deg.C for pack two
D: 24 deg.C for pack one and 15 deg.C for pack two
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
5: In normal flight in closed circuit configuration, the avionics ventilation system controls the temperature of the cooling air by:
A:'Adding air conditioned air to the flow
B: Extracting air overboard
C: Adding avionics bay air
D: Passing air through a skin heat exchanger
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
6: To enable Ram air to the mixture unit, The Ram air switch should be used:
A: At any time
B: Only when differential pressure is less than 1 psi.
C: When pressure is greater than 1 psi diff.
D: Only after outflow valve is fully opened
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
7: Pack controller, primary channel failure.
A: The secondary computer operates as a backup mode and regulation is not optimized
B: The secondary computer takes over (all functions as normal)
C: Pack is lost
D: Pack outlet temperature is controlled at 15 deg.C