S9.2 Rescode 55 Part 2

S9.2 Rescode 55 Part 2

University

25 Qs

quiz-placeholder

Similar activities

AR 490 - Building Utilities - Quiz (Post-Lecture)

AR 490 - Building Utilities - Quiz (Post-Lecture)

University

20 Qs

WEEK 8 (2022)_SANITARY APPLIANCES & TRAP

WEEK 8 (2022)_SANITARY APPLIANCES & TRAP

University

20 Qs

EVALUASI ESTIMASI DAN PERENCANAAN

EVALUASI ESTIMASI DAN PERENCANAAN

11th Grade - University

20 Qs

Chapter 2 Water Supply System in Buildings (True/False)

Chapter 2 Water Supply System in Buildings (True/False)

University

20 Qs

What Type of Lighting?

What Type of Lighting?

University

20 Qs

VDA - Ceramic

VDA - Ceramic

University

20 Qs

Ancient Architecture

Ancient Architecture

KG - University

20 Qs

TROPICAL DESIGN FINAL EXAM ODAR3

TROPICAL DESIGN FINAL EXAM ODAR3

University

20 Qs

S9.2 Rescode 55 Part 2

S9.2 Rescode 55 Part 2

Assessment

Quiz

Architecture

University

Practice Problem

Hard

Created by

Chris Ho

Used 5+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Media Image

What is the minimum dimension clear to the sky that must be maintained for the light court next to an existing habitable room window?

0.5 meters

1 meter

1.5 meters

2 meters

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Media Image

What is the minimum area of the light court next to an existing habitable room window?

1 sqm

2 sqm

3 m

3 sqm

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Can the eaves encroach on the space required for the light court to ensure daylight to an existing window?

Yes, as long as light is not obstructed

Yes, but only by 0.5 meters

No, eaves cannot encroach on this space

No, unless special permission is granted

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Media Image

What is the angle of the arc within which a new wall must fall if it is to be within the daylight access range of an existing window?

25° arc from the center of the existing window

35° arc from the center of the existing window

45° arc from the center of the existing window

55° arc from the center of the existing window

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Media Image

What is the 3m high wall setback from the exisiting habitable room window in the diagram, if the wall is within 55 deg arc from center of exisitng window?

Half

one quarter

25%

60%

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

How far should a building be set back from the boundary if a north-facing habitable room window of an existing dwelling is within 3 meters of the boundary on an abutting lot and the building height is 5 meters?

1.84 meters

2.4 meters

1 meter

2 meters

7.

MULTIPLE SELECT QUESTION

1 min • 1 pt

A north-facing window is a window with an axis perpendicular to its surface oriented?

north 20 degrees east

north 20 degrees west

north 30 degrees east

north 30 degrees west

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?