Search Header Logo

Heat Pump Study Guide

Authored by Michael Wilson

Science

12th Grade

NGSS covered

Used 7+ times

Heat Pump Study Guide
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

100 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

With an R-410A condensing pressure of 395 psig and a liquid line temperature of 108°F what is the sub cooling temperature?

A. Cool
B. 3 psi
B. 30°F
D. 8°F

Tags

NGSS.HS-PS3-4

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When performing maintenance on a heat pump the technician should check the outdoor fan to be certain:

C. The maximum fuse or a circuit breaker size
C. The fan runs freely without binding or vibrations
B. The relative humidity is very high
D. The valve will vibrate or chatter

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The continuity of a fuse in a disconnect should be tested by checking resistance:

A. Volts
C. 500 microns
A. With power off
A. Cool

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why does the outdoor fan on a heat pump stopped during defrost?

D. On the shorter sides
C. Additional resistor
C. 500 microns
C. Minimize defrost time

Tags

NGSS.HS-PS3-4

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

It technician measures the return air temperature of 100,000 BTU output furnace to be 65°F and the supply side air temperature is 135°F. what is the SCFM(standard CFM)?

B. 3 psi
C. 25 amps
B. 30°F
B. 1323 SCFM

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The following measurements are recorded on an operating heat pump system. The heat pump is operating with the compressor only with no auxiliary heat.-heat pump only supply air temperature 92°F, heat pump only return air temperature 70°F, outdoor temperature 54°F, supply air temp./Auxiliary heat on 115°F, return air temp./Auxiliary heat on 70°F, CFM 1228What is the heating capacity of the unit in BTU/H?

B. 0.5 IWC
C. 25 amps
D. 5000 V
D. 29,177 btu/h

Tags

NGSS.HS-PS3-4

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

R-410A Vapor in line diameters with links 50 feet or less are typically specified for a vapor pressure drop that does not exceed what value?

A. Volts
B. 3 psi
B. 0.5 IWC
B. 30°F

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?