Gas Pipework Installation Quiz no4

Gas Pipework Installation Quiz no4

1st Grade

27 Qs

quiz-placeholder

Similar activities

PENGUATAN MATERI PKS 4

PENGUATAN MATERI PKS 4

1st Grade

30 Qs

Pertambangan part 5

Pertambangan part 5

1st - 5th Grade

22 Qs

Control de Infecciones

Control de Infecciones

1st - 2nd Grade

22 Qs

ELEMENTARY EXAM AUGUST

ELEMENTARY EXAM AUGUST

1st - 5th Grade

23 Qs

work effectively with others - TEST 2- (19.1.2022)

work effectively with others - TEST 2- (19.1.2022)

1st Grade - Professional Development

23 Qs

SOAL UJIAN ADUM X SEM. GENAP KD.3.7,3.8,3.9

SOAL UJIAN ADUM X SEM. GENAP KD.3.7,3.8,3.9

1st Grade

25 Qs

Equality and Diversity

Equality and Diversity

KG - 5th Grade

22 Qs

AES - Pneudraulic System

AES - Pneudraulic System

KG - Professional Development

25 Qs

Gas Pipework Installation Quiz no4

Gas Pipework Installation Quiz no4

Assessment

Quiz

Professional Development

1st Grade

Practice Problem

Hard

Created by

Graham Rogerson

Used 2+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

27 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum interval between horizontal pipework supports for 15 mm copper gas pipework installed between solid timber joists is:

1.0 m.

1.5 m.

2.5 m.

3.5 m.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The minimum size solid timber joist that can be notched for a gas pipe is:

50 mm.

75 mm.

100 mm.

150 mm.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where gas pipework is buried in a floor screed, what is the minimum cover above the pipe?

5 mm.

10 mm.

25 mm.

100 mm.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Gas pipework installed behind dry lining shall:

Be made of steel only.

Need no additional protection.

Be suitably wrapped in tape only.

Be suitably encased by building material.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Gas pipework installed within walls of timber frame and light steel-framed construction shall:

Be made of steel only.

Have only welded joints.

Be left unsupported to allow for movement.

Be run within purpose-designed channels or ducts.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Above ground external gas pipework shall be protected against:

Painting

The weather

The risk of mechanical damage

The risk of unauthorised alterations

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Polyethylene (PE) gas pipework in private gardens, with no vehicular traffic, shall have a MINIMUM depth of cover of:

375 mm with marker tape between 75 mm above the pipework

450 mm with marker tape between 75 mm above the pipework

375 mm with marker tape between 100 mm and 300 mm above the pipework

450 mm with marker tape between 100 mm and 300 mm above the pipework

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?