Tightness Testing and IGEM/UP/1B

Tightness Testing and IGEM/UP/1B

Professional Development

10 Qs

quiz-placeholder

Similar activities

Pre Test HACCP

Pre Test HACCP

Professional Development

10 Qs

Principles of Food Hygeine_1

Principles of Food Hygeine_1

Professional Development

10 Qs

Agile SL701B

Agile SL701B

University - Professional Development

10 Qs

Chemistry 10-4-1 week

Chemistry 10-4-1 week

7th Grade - Professional Development

15 Qs

Course Audit - Summative Assessment # 2

Course Audit - Summative Assessment # 2

Professional Development

10 Qs

motion and measurement of distances

motion and measurement of distances

KG - Professional Development

10 Qs

The Red Lotus x Zephyr Webinar

The Red Lotus x Zephyr Webinar

KG - Professional Development

8 Qs

The impact of COVID-19 on dental health and education

The impact of COVID-19 on dental health and education

University - Professional Development

10 Qs

Tightness Testing and IGEM/UP/1B

Tightness Testing and IGEM/UP/1B

Assessment

Quiz

Science

Professional Development

Practice Problem

Hard

Created by

Rob Anderson

Used 14+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum installation volume (IV) that can be worked on as per IGEM/UP/1B?

0.025m3

0.035m3

0.02m3

0.2m3

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum operating pressure (MOP) at the outlet of the emergency control valves (ECV) as per IGEM/UP/1B?


75mb


1bar


2bar


3bar

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum nominal bore for copper pipework as per IGEM/UP/1B?

22mm

28mm


35mm



45mm

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When conducting a let-by test the water within the U gauge raises by more than 0.25mb, what procedure would you follow?


The test would be stopped and ESP called to repair

Disconnect the ECV and spray LDF into the barrel to prove you have let-by.


Move straight onto the tightness test suspected let-by would have no detrimental affect on the test.

Connect temporary bonding across the meter than disconnect the ECV and spray LDF into the barrel to prove let-by before contacting ESP.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

      What is the maximum pressure drop allowed for an existing system with appliances fitted, a G4 meter and 35mm pipework, appliance connected and no smell of gas reported?


4mb

0mb


8mb

2.5mb

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The normal working pressure of a low pressure installation is?

19mb

20mb ± 1mb



21mb ± 2mb


23mb

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the let-by test pressure on both low and medium pressure installations?

12mb

20mb


20-21mb

7-10mb

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?