PROFESSIONAL ELECTRICAL ENGINEERING

PROFESSIONAL ELECTRICAL ENGINEERING

Assessment

Quiz

Mathematics

University

Medium

Created by

Sonia Tabalan

Used 1+ times

FREE Resource

100 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

At time t = 0 the charge on the 50-µF capacitor in an LC circuit is 15 µC and there is no current. If the inductance is 20 mH the maximum current is:

12 nA

15 μΑ

15mA

15 A

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In the left-hand rule, thumb always represents direction of the ________.

voltage

force on conductor

current

magnetic field

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Three capacitances C₁= 6 µF, C₂ = 7 µF and C3 = 18 µF are connected in series across a 120 v supply. Find the voltage across C2.

65.22 v

18.26 v

46.96 v

54.78 v

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A balanced delta connected load has impedances Z1 = Z2 = Z3. What is the per phase equivalent impedance in wye?

Z1/3

3Z1

2Z1 /3

Z1

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The net reactance in an RCL circuit is

XL

Xc

XC-XL

XL-XC

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the largest rated room air conditioner unit that may he attached to a 20-ampere branch circuit that also serves other receptacles?

10

12

15

16

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A 60-Hz short transmission line, having R = 0.62 ohms per phase and L = 93.24 mH per phase, supplies a three-phase, wye-connected 100 MW load of 0.90 lagging power factor at 230 kV line-to-line voltage. Determine the voltage regulation of the transmission line?

3.75%

3.20%

3.55%

3.42%