Unit 43 #3

Unit 43 #3

9th - 12th Grade

10 Qs

quiz-placeholder

Similar activities

Automotive Starters

Automotive Starters

12th Grade - University

13 Qs

Refrigerant Components and Cycle

Refrigerant Components and Cycle

9th - 12th Grade

10 Qs

AYISHA M -CEEY 258 CAT2

AYISHA M -CEEY 258 CAT2

12th Grade

15 Qs

Draft HVAC System Layout

Draft HVAC System Layout

9th Grade

10 Qs

cooling system check

cooling system check

12th Grade

10 Qs

Energy Efficiency Quiz

Energy Efficiency Quiz

6th Grade - University

10 Qs

Summer School Physical Science - CH 8 - Section II

Summer School Physical Science - CH 8 - Section II

9th - 11th Grade

10 Qs

Cooling System

Cooling System

10th Grade - Professional Development

11 Qs

Unit 43 #3

Unit 43 #3

Assessment

Quiz

Other

9th - 12th Grade

Hard

Created by

c Romanski

Used 4+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

System overshoot and temperature swing are controlled by a device known as a(n)

anticipator.

regulator.

moderator.

Capillary tube

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The term "balance point" is best described as

the lowest temperature at which a heat pump system can heat a structure without the aid of any supplementary heat.

the lowest temperature at which a heat pump's electric strip heaters can heat a structure.

the point where the heating and cooling capacities of a heat pump system are equal to each other.

the point where the heat pump's supplementary heating capacity exactly offsets the system's cooling capacity.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In the emergency heat mode, what percentage of the heat pump system's electric strip heaters will be energized?

50%

100%

75%

25%

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following statements is true regarding SEER and HSPF?

SEER is an efficiency rating for cooling, while HSPF is an efficiency rating for heating.

SEER is an efficiency rating for heating, while HSPF is an efficiency rating for cooling.

Both SEER and HSPF are efficiency ratings for cooling.

Both SEER and HSPF are efficiency ratings for heating.

5.

MULTIPLE SELECT QUESTION

30 sec • 1 pt

Which of the following is true regarding package-type heat pump systems?

They are charged at the factory and bench-tested before they are shipped.

They are shipped with a holding charge of dry nitrogen.

All field-installed refrigerant lines must be insulated.

Only the larger of the two field-installed refrigerant lines must be insulated.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following best describes the operation of second-stage heat on a heat pump system?

Last on, last off

First on, last off

First on, first off

Last on, first off

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following statements is true regarding the cooling cycle of a heat pump system?

The compressor cycles on when the thermostat's selector switch is set to the cooling mode and the reversing valve's coil energizes and deenergizes depending on the space temperature.

The coil on the reversing valve is energized when the thermostat's selector switch is set to the cooling mode and the compressor cycles on and off depending on the space temperature.

Both the compressor and the reversing valve's coil are energized when the thermostat's selector switch is set to the cooling mode and the reversing valve's coil energizes and deenergizes depending on the space temperature.

Neither the compressor nor the reversing valve's coil are energized when the thermostat's selector switch is set to the cooling mode, but they are both energized and deenergized depending on the space temperature.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?