Preceptorship MCQs

Authored by LVPEI Academy

Other

Professional Development

Preceptorship MCQs
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

6 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

1.    Which among the following is true for Goldman Applanation tonometer?

a. Constant force, constant area

b. Variable force, variable area

c. Constant force, variable area

d. Variable force, constant area

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

2. Which of the following is true for Goldman applanation tonometer?

a. Diameter of external area of Corneal applanation is 3.06mm

b. Diameter of external area of Corneal applanation is 7.35mm

c. Internal area of applanation obtained is 7.35mm2

d. Internal area of applanation

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

3. All of the following may result in underestimation of IOP except:

a. Post LASIK

b. Post PRK

c. Corneal edema

d. Corneal scar

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

4. Which among the following statements are correct ?

a. For every 3 diopters (D) of increase in corneal astigmatism power, IOP increases by 1mmHg

b. Orienting the applanation head so the split rings occurred over the flat meridian and then orienting the rings over the steep meridian. The mean of the two pressures produced a reading close to the true intraocular pressure reading

c. Readings can be taken with the tonometer head in the usual horizontal position and then the tonometer head be twisted 90”and another reading be taken. The sum of the horizontal and vertical applanation head readings should be averaged and the average should be considered the IOP.

d. Both a and b are correct

e. All of the above are correct

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

5. How frequently a Goldman applanation tonometer needs to be calibrated?

a.  Every month

b. Every year

c. Once in 3 years

d. Never

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

  1. 6. What is the recommended acceptable range of Calibration error for Goldman applanation tonometer?

a. +/-0.5 mmHg at all 3 levels of testing

b. +/-1 mmHg at all 3 levels of testing

c. +/-2 mmHg at all 3 levels of testing

d.  All of the above

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?