1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The risk of electric shock during fault finding can be greatly reduced if
The supervisor keeps the keys to any lock off devices
All employees have the same qualifications and experience
All isolators and switches are correctly labelled
Only calibrated test equipment is used
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of these pictures shows the correct setting for using a multimeter to safely measure a.c voltage?
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
During the periodic inspection of an industrial installation, the engineer notes the absence of any main protective bonding. What action should the engineer take?
Identify on an Electrical Installation Condition Report, that there is a potentially dangerous situation and urgent remedial action is required
Isolate the installation and classify as C1 on a Periodic Inspection Report, to identify that there is danger present and immediate remedial action is needed
Tell the owner that having no protective bonding is classified as C3, and an improvement is recommended
Inform the person responsible for the installation, that it does not comply with BS 7671, but it is not unsafe
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
A safe system of work has been planned for a large installation. Which document will need to be produced?
Permission to operate
Secure system of operation
Building control notification
Permit to work
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
When should maintenance reports and records by fully completed for any repair work?
Within 3 months
When the repair is finished
Halfway through the job
Within 1 month
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
An electrician is working in a small high street shop and explains to the owner that it is necessary to isolate the electrical supply. In order to safeguard his customers what should the owner do?
Only allow a limited number of customers into the shop
Close the shop until power is restored
Have staff escort customers round the shop
Install temporary lighting
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
An engineer has just completed an Electrical Installation Condition Report. What action should the engineer now take?
The local Authority should be sent the original report, and a copy given to the person who ordered the report
The person ordering the report should be given the original report and the engineer should keep a duplicate copy
The owner of the installation should be given the original report, with a copy going to the Local Authority, and the person who requested the report, if this is not the owner.
The engineer should keep the original report, and send a copy to the National Inspection Council