QUIZ: Methanol Content as per BS EN 14110

QUIZ: Methanol Content as per BS EN 14110

Professional Development

9 Qs

quiz-placeholder

Similar activities

Task 2 - Fossil Fuels Quiz

Task 2 - Fossil Fuels Quiz

Professional Development

5 Qs

C 6 Planification d'un voyage Manchester NH

C 6 Planification d'un voyage Manchester NH

Professional Development

12 Qs

C 6 Planification d'un voyage Barre VT

C 6 Planification d'un voyage Barre VT

Professional Development

14 Qs

Questionnaire de satisfaction "prise de parole en public"

Questionnaire de satisfaction "prise de parole en public"

Professional Development

8 Qs

Natural Gas Quiz

Natural Gas Quiz

Professional Development

13 Qs

ASSESSMENT GLOBAL MINDSET

ASSESSMENT GLOBAL MINDSET

Professional Development

10 Qs

Write the gerund

Write the gerund

Professional Development

8 Qs

MARC TEÒRIC A1

MARC TEÒRIC A1

Professional Development

11 Qs

QUIZ: Methanol Content as per BS EN 14110

QUIZ: Methanol Content as per BS EN 14110

Assessment

Quiz

others

Professional Development

Easy

Created by

Amira Zahari

Used 5+ times

FREE Resource

9 questions

Show all answers

1.

OPEN ENDED QUESTION

30 sec • Ungraded

Full Name

Evaluate responses using AI:

OFF

2.

OPEN ENDED QUESTION

30 sec • Ungraded

VM Num

Evaluate responses using AI:

OFF

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the sample quantity?
1 mL
2 mL
3 mL
4 mL

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What sample uses 2 mL sample quantity?
PME reactors
RG product
PME product
Palm TRF product

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What instrument do we use to measure 2 mL sample?
2 mL dropper
2 mL micropipette
5 mL micropipette

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How to make sure vial has been crimpt tightly?
Blow on the vial
Shake the vial
Do a twist-test on the vial cap
Drop the vial

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why do we need to crimp the vial tightly?
So that the cap is not missing
Because the cap is expensive
To make sure sample is not leaking
To make sure methanol did not leak from the vial

8.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

If a chromatogram report shows an error as described, what does it signify?

It signifies a data entry error in the chromatogram report.

It signifies a problem with analysis where the peak analyzed are out of equipment's calibration

It signifies a problem with analysis where the peak analyzed are out of calibration range

It signifies a successful separation of compounds during the chromatography process.

9.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

At what temperature does methanol typically reach equilibrium in a gas chromatography headspace analysis before being injected into the GC system

30-50 degrees Celsius
50-70 degrees Celsius
20-40 degrees Celsius

60-80 degrees Celsius