Inspection and Testing - 15Q Mock Quiz

Inspection and Testing - 15Q Mock Quiz

Vocational training

15 Qs

quiz-placeholder

Similar activities

meter cert 2

meter cert 2

12th Grade

15 Qs

Inspection and testing

Inspection and testing

1st - 3rd Grade

17 Qs

DET10013 RE-CAP CHAPTER 1 PART 1

DET10013 RE-CAP CHAPTER 1 PART 1

University

10 Qs

Resistors in Parallel

Resistors in Parallel

9th - 10th Grade

11 Qs

Safe isolation and dead testing NETk3-06

Safe isolation and dead testing NETk3-06

Professional Development

18 Qs

Basic Concept of Electricity and Electronics

Basic Concept of Electricity and Electronics

6th Grade

10 Qs

ACE DAY 3

ACE DAY 3

Professional Development

10 Qs

monthly test for the month of january 2025

monthly test for the month of january 2025

KG - University

20 Qs

Inspection and Testing - 15Q Mock Quiz

Inspection and Testing - 15Q Mock Quiz

Assessment

Quiz

Other

Vocational training

Hard

Created by

Costagis Yianni

Used 12+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When a certificate is issued for Initial Verification purposes, for the certificate to be valid it MUST be accompanied by?

inspection tick-sheet

test results sheet

schedules of inspections and test results

Part 'P' certificate

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When the installation of a new circuit to an existing installation has been completed, the inspector will issue?

an initial verification certificate

a schedule of the tests completed

a minor-works certificate

a condition report

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

An electrical installation certificate for a new installation will require THREE signatories, Identify one of these signatories.

the local authority

the designer

the site manager

the owner

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the human senses would be used to determine that a BS3036 device has operated?

hearing

sight

smell

touch

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which (preferred) human sense would be used to determine that a flex is being exposed to over-current?

hearing

touch

sight

smell

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Identify the indication to be used on an Initial Verification Schedule of Inspection form to indicate that an item meets the requirements of BS7671

Lim

N/A

a tick

a cross (x)

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Supplementary bonding conductors that are protected against mechanical damage shall have a CSA no smaller than?

10 sqmm

6 sqmm

2.5 sqmm

4 sqmm

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?