1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
13. (405) Which delivery pressure causes the fueling side of the 302AF fueling and defueling valve toclose when turning the adjusting screw on the loading pressure-relief control (CRL)counterclockwise?
b. 5 psi above normal operating pressure (NOP).
a. 5 pounds per square inch (psi) above normal inlet pressure.
c. 10 psi above normal inlet pressure.
d. 10 psi above NOP.
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
25. (409) What pressure rate must you establish before setting the pressure-relief control (CRL) on the 90AF–8 refueling control valve (RCV)?
a. 2 to 3 pounds per square inch (psi) above normal downstream pressure.
b. 2 to 3 psi above normal upstream pressure.
c. 5 psi above normal downstream pressure.
d. 5 psi above normal upstream pressure.
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
50. (419) The ball float for the 413AF–5A high-level shutoff valve (HLV) on an operating storage tank is located on
a. top of the tank in the float well.
b. top of the tank in the gauging well.
c. the exterior side of the tank at the required shutoff height.
d. the interior side of the tank at the required shutoff height.
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
91. (427) What type of piping is used with the Type IV issue filter/separators (F/S), the system loop, and receiving loop when a 6-inch pipe is used?
a. Seamless stainless steel, schedule 40.
b. Seamless stainless steel, schedule 80.
c. Epoxy-coated carbon steel, schedule 40.
d. Epoxy-coated carbon steel, schedule 80.
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
123. (436) During pantograph flushing, how many seconds does the operator have to depress the deadman control on the refueling control valve (RCV) before the pumps shut off due to high pressure?
a. 5.
b. 10.
c. 15.
d. 20.
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
59. (419) What valve is used as an overfill valve (OV) for the product-recovery tank in the Type III system?
a. 129AF.
b. 2029AF.
c. 2129AF.
d. 136AF–9B.
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
18. (407) Which lateral control pit (LCP) component automatically cuts off the defuel pump when a predetermined amount of inches of mercury is reached?
a. Solenoid control switch.
b. Pump circuit breaker.
c. Vacuum control switch.
d. Panel selector switch.
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?