Phase4Mod5Pipework

Phase4Mod5Pipework

Professional Development

11 Qs

quiz-placeholder

Similar activities

Phase 1 PP 5

Phase 1 PP 5

Professional Development

10 Qs

Hot Water Systems Quiz

Hot Water Systems Quiz

Professional Development

10 Qs

PP 11 Central Heating System Quiz

PP 11 Central Heating System Quiz

Professional Development

10 Qs

phase4.mod14.flue config.

phase4.mod14.flue config.

Professional Development

6 Qs

Structures of a volcano!

Structures of a volcano!

9th Grade - Professional Development

10 Qs

Gas Installation and Tightness Test Quiz

Gas Installation and Tightness Test Quiz

Professional Development

15 Qs

17 Days of SDGs  Quiz - Day 14 (English)

17 Days of SDGs Quiz - Day 14 (English)

3rd Grade - Professional Development

15 Qs

PP 12 Central Heating Decommissioning Quiz

PP 12 Central Heating Decommissioning Quiz

Professional Development

6 Qs

Phase4Mod5Pipework

Phase4Mod5Pipework

Assessment

Quiz

Science

Professional Development

Hard

Created by

Craig Boothright

Used 4+ times

FREE Resource

11 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When protection against corrosion is used, the protection applied must:

Extend at least 25mm beyond the corrosive surface.

Extend at least 50mm beyond the corrosive surface.

Extend at least 75mm beyond the corrosive surface.

Extend at least 100mm beyond the corrosive surface.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A compression joint is acceptable for use on gas pipework. Which of the following situations should compression fittings be avoided?

Within Garages.

In Bedrooms.

Beneath floorboards.

Within a roof space.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Wrapping a gas pipe as it passes through a wall is acceptable as an alternative to pipe sleeving if a 55% overlap is used

True.

False.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

No person shall install any gas installation pipework in a shaft, duct or void which is not adequately ventilated to?

Ensure that minor gas escapes (within the permitted leakage rate) do not build up and create an unsafe situation.

Prevent the pipework from overheating.

Prevent the pipework from corroding.

Allow for expansion and contraction of the pipework.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When pipework is buried beneath the ground used for pedestrian traffic, it should be buried at least:

275mm below the surface.

300mm below the surface.

375mm below the surface.

550mm below the surface.

6.

FILL IN THE BLANK QUESTION

1 min • 1 pt

Prior to the connection of any pipework to an existing gas installation , the gas operative must:

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Excessive flux applied to pipe fittings prior to soldering may cause a partial blockage within the pipework. Which of the following is not a consequence of this fault?

Increased pressure to appliances.

Increased pressure loss through the fitting

Corrosion of the pipe from inside in the future.

Unsound joints being temporarily sealed with excess flux.

Create a free account and access millions of resources