Rubber gloves are used to prevent

Module 26102-20 - Section 2 Review

Quiz
•
Other
•
Vocational training
•
Medium

Jahmicah Miller
Used 4+ times
FREE Resource
9 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
2 mins • 10 pts
clothing from burning into the skin during arc blast
the skin from coming in contact with de-energized circuits
the skin from the sharp edges of an electrical panel
the skin from coming in contact with energized circuits
Answer explanation
MODULE 26102-20
PAGE 10
PARAGRAPH 2
2.
FILL IN THE BLANK QUESTION
1 min • 10 pts
Periodic inspection and testing of protective equipment is required by
3.
MULTIPLE CHOICE QUESTION
2 mins • 10 pts
The following statements are true about CLASS E hard hats, except
CLASS E hard hats are required when employees are exposed to high voltage hazards
CLASS E hard hats have the lowest rating
CLASS E hard hats can withstand 20,000 VAC for three minutes
CLASS E hard hats should be replaced every five years
4.
MULTIPLE CHOICE QUESTION
1 min • 10 pts
What does ANSI stand for?
American National Safety Institute
American National Standard Institute
5.
MULTIPLE CHOICE QUESTION
45 sec • 10 pts
How often should insulating gloves be electrically tested?
every year
each day before use
at the beginning of the work shift
every six months
6.
MULTIPLE SELECT QUESTION
45 sec • 10 pts
Which of the following can damage rubber gloves?
Wearing watches
Wearing rings
Wearing Bracelets
Nonconductive material
Answer explanation
Wearing any conductive material defeats the purpose of wearing the rubber gloves in the first place.
Module 26102-20, Page 13, Section 2.2.2
7.
MULTIPLE CHOICE QUESTION
1 min • 10 pts
All of the following would case a rubber glove to be suspect or defective, except
hardening
slight cracking
glove dust
petroleum exposure
8.
MULTIPLE CHOICE QUESTION
1 min • 10 pts
What type of clothing would increase the severity of a arc blast burn?
polyester fabric
cotton fabric
nonflammable clothing
leather
Answer explanation
Module 26102-20
Page 15
Section 2.2.4
9.
MULTIPLE CHOICE QUESTION
2 mins • 10 pts
Hot sticks are used for all of the following, except
manual operation of disconnecting switches
confirming voltage on a potentially energized circuit
removal and install of temporary grounds
fuse removal and insertion
Answer explanation
Module 26102-20
Page 15
Section 2.2.5
Similar Resources on Wayground
13 questions
PBIS Review

Quiz
•
6th - 8th Grade
11 questions
Vocabulary for U2, C1

Quiz
•
10th Grade
8 questions
krunker

Quiz
•
1st Grade
13 questions
Workplace Skills Quiz

Quiz
•
9th Grade
10 questions
Boy, Were We Wrong About Dinosaurs!

Quiz
•
3rd - 4th Grade
10 questions
Formative Question DET50083 Power System Protection

Quiz
•
University
10 questions
Skin, hair and nails

Quiz
•
7th Grade
12 questions
Personal Hygiene

Quiz
•
KG - 12th Grade
Popular Resources on Wayground
25 questions
Equations of Circles

Quiz
•
10th - 11th Grade
30 questions
Week 5 Memory Builder 1 (Multiplication and Division Facts)

Quiz
•
9th Grade
33 questions
Unit 3 Summative - Summer School: Immune System

Quiz
•
10th Grade
10 questions
Writing and Identifying Ratios Practice

Quiz
•
5th - 6th Grade
36 questions
Prime and Composite Numbers

Quiz
•
5th Grade
14 questions
Exterior and Interior angles of Polygons

Quiz
•
8th Grade
37 questions
Camp Re-cap Week 1 (no regression)

Quiz
•
9th - 12th Grade
46 questions
Biology Semester 1 Review

Quiz
•
10th Grade