Cable Technology Quiz

Cable Technology Quiz

12th Grade

30 Qs

quiz-placeholder

Similar activities

Electrical Wiring Test

Electrical Wiring Test

9th - 12th Grade

34 Qs

M7_Topic C

M7_Topic C

10th Grade - University

25 Qs

Electrical Safety and Cable Knowledge Quiz

Electrical Safety and Cable Knowledge Quiz

12th Grade

30 Qs

Electrical Cables Quiz

Electrical Cables Quiz

12th Grade

29 Qs

Cable and Electrical Safety Quiz

Cable and Electrical Safety Quiz

12th Grade

35 Qs

Ag. Mechanics 1 Electrical

Ag. Mechanics 1 Electrical

9th - 12th Grade

26 Qs

Electrical Engineering Quiz

Electrical Engineering Quiz

12th Grade

29 Qs

Electrical Engineering Quiz

Electrical Engineering Quiz

12th Grade

30 Qs

Cable Technology Quiz

Cable Technology Quiz

Assessment

Quiz

Other

12th Grade

Easy

Created by

Yusuf Abubakar

Used 1+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Full form of PILCSTA on cables

Paper insulated lead covered steel wire armoured

Plastic insulated lead covered steel wire armoured

Paper insulated lead covered steel tape armoured

Paper insulated laminated copper steel tape armoured

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

3c 300 SAC XLPE 11Kv on a cable record means

3 core 300sqmm Copper unsheathed 11KV

3 x 1 core 300sqmm Aluminium lead sheathed 11 KV

3 Core 300sqmm Solid Aluminium Conductor 11KV

3Core 300sqmm Stranded Copper Conductor 11KV

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The acronym XLPE refers to

Plain lead covered earth cable

Mineral insulated cable

Cross linked polyethylene insulated cable

Point on a cable plan where a cable is laid on top of another cable.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of gas is used in a gas filled cable?

Carbon Dioxide

Oxygen

Helium

Nitrogen

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The purpose of screening 3-phase high voltage cables is to

Stop electrolytic action

Control tangential stresses

Provide good earth continuity

Give extra mechanical protection

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On a cable plan the letters ABSD may appear. This would refer to

Aerial bundled steel distributer

Air blast system disengager

Air break switch disconnector

Aerial balanced safety distancer

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When handling cold pour resins the mandatory PPE would be

Overalls and eye protection

Disposable gloves and breathing apparatus

Breathing apparatus and overall

Eye protection and disposable gloves.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?