Unit 21 Flashcards (QUIZ) (CRF)-Mr. Graham

Unit 21 Flashcards (QUIZ) (CRF)-Mr. Graham

University

10 Qs

quiz-placeholder

Similar activities

Sistem Starter

Sistem Starter

11th Grade - University

10 Qs

Refrigeration Cycle 2

Refrigeration Cycle 2

University

13 Qs

FUN 101 week 1

FUN 101 week 1

University

13 Qs

SISTEM STARTER SEPEDA MOTOR

SISTEM STARTER SEPEDA MOTOR

11th Grade - University

10 Qs

M3 - QUIZ NO. 3

M3 - QUIZ NO. 3

University

14 Qs

POSTEST FORMATIF (SISTEM EFI)

POSTEST FORMATIF (SISTEM EFI)

11th Grade - University

9 Qs

PROGRAMMABLE LOGIC CONTROLLER

PROGRAMMABLE LOGIC CONTROLLER

University

6 Qs

Welding Knowledge Quiz

Welding Knowledge Quiz

9th Grade - University

15 Qs

Unit 21 Flashcards (QUIZ) (CRF)-Mr. Graham

Unit 21 Flashcards (QUIZ) (CRF)-Mr. Graham

Assessment

Quiz

Instructional Technology

University

Easy

Created by

Randall Graham

Used 3+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 10 pts

The boiling temperature of the liquid can be controlled by controlling the pressure. The standard boiling pressure for water is and atmospheric pressure of 29.92 in. Hg (mercury) where water boils at 212° F.

Boiling Temperature

Film Factor

Saturated Vapor

Starved Coil

2.

MULTIPLE CHOICE QUESTION

30 sec • 10 pts

The Relationship between the medium giving up heat and the heat exchange surface (evaporator). This relates to the velocity of the medium passing over the evaporator. When the velocity is too slow, the film between the air and the evaporator becomes greater and becomes an insulator, which slows the heat exchanger.

Bearing Washout

Film Factor

Wet Compression

Starved Coil

3.

MULTIPLE CHOICE QUESTION

30 sec • 10 pts

An evaporator that has stamped refrigerant passages in sheet steel or aluminum.

Film Factor

Flooded Evaporators

Starved Coil

Stamped Evaporator

4.

MULTIPLE CHOICE QUESTION

30 sec • 10 pts

The condition in the evaporator when the metering device is not feeding enough refrigerant to the evaporator.

Flooded Evaporators

Finned Tube Evaporator

Starved Coil

Bearing Washout

5.

MULTIPLE CHOICE QUESTION

30 sec • 10 pts

A refrigerant system operated with the liquid refrigerant level very close to the outlet of the evaporator coil for improved heat exchange.

Subcooling

Flooded Evaporators

Superheat

Finned Tubed Evaporator

6.

MULTIPLE CHOICE QUESTION

30 sec • 10 pts

The refrigerant when all of the liquid has just changed to a vapor.

Saturated vapor
Superheated vapor
Saturated liquid
Liquid refrigerant

7.

MULTIPLE CHOICE QUESTION

30 sec • 10 pts

A copper or aluminum tube that has fins, usually made of aluminum, pressed onto the copper lines to extend the surface area of the tubes.

Finned tube evaporator

Condenser coil
Radiator core
Heat sink

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?