GMJ 6189 CH

GMJ 6189 CH

Vocational training

58 Qs

quiz-placeholder

Similar activities

A1 Health and Safety in Construction

A1 Health and Safety in Construction

11th Grade - University

58 Qs

Unit 101 Short Answer AI Test 2 SE HW

Unit 101 Short Answer AI Test 2 SE HW

1st Grade - University

60 Qs

UJIAN KOMPETENSI TEKNIK BANGUNAN DAN LANDASAN ANGKATAN 15 A/B

UJIAN KOMPETENSI TEKNIK BANGUNAN DAN LANDASAN ANGKATAN 15 A/B

KG - University

57 Qs

Learning Objectives - Construction Team Roles

Learning Objectives - Construction Team Roles

KG - University

54 Qs

Carpentry EOPA Part 2

Carpentry EOPA Part 2

9th - 12th Grade

53 Qs

Key Content Areas - C1 Heat

Key Content Areas - C1 Heat

11th Grade

60 Qs

Revision 2

Revision 2

KG - University

60 Qs

Level One- PPE

Level One- PPE

KG - University

61 Qs

GMJ 6189 CH

GMJ 6189 CH

Assessment

Quiz

Construction

Vocational training

Practice Problem

Medium

Created by

Glen Johnson

Used 2+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

58 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Which one of the following types of heating system uses the components shown in the image below?

S plan

Y plan

W plan

C plan

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A heating system can be installed without separated timed space heating zones in a domestic dwelling, providing the floor area is not larger than?

100 m2

150 m2

1000 m2

1500 m2

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following recognises the outside temperature and regulates the boiler heat output accordingly?

Room thermostat

Anemometer

Cavity thermostat

Weather compensator

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The combination of a fan and heat exchanger is used in the installation of which one of the following?

Micro combined heat and power

Air source heat pump

Ground source heat pump

Biomass heating system

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following components is designed to minimise the amount of uncontrolled energy from the pipework in an under floor heating system?

Gravity valve

Pump

Manifold

Pipe coil

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The main function of an under floor heating manifold when fitted with flow metres is to

Measure water flow

Aid system balancing

Isolate heating appliances

Aid chemical treatment

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended maximum number of circuits when a single manifold is used on an under floor heating system, in order to avoid overheating?

4-7

8-9

10-12

15-18

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?