SDBA & UBBL

SDBA & UBBL

University

9 Qs

quiz-placeholder

Similar activities

Building Services QUIZ (10%)

Building Services QUIZ (10%)

University

6 Qs

Quiz: Spatial Strategies for Environmental Responsiveness

Quiz: Spatial Strategies for Environmental Responsiveness

University

10 Qs

Loft and Attic Quiz

Loft and Attic Quiz

University

10 Qs

Quiz 2

Quiz 2

University

12 Qs

ArchDes Quiz 4

ArchDes Quiz 4

KG - Professional Development

10 Qs

Stairs Construction Quiz

Stairs Construction Quiz

University

13 Qs

Building Services 1

Building Services 1

University

10 Qs

CT2 Mid Term 1

CT2 Mid Term 1

University

10 Qs

SDBA & UBBL

SDBA & UBBL

Assessment

Quiz

Architecture

University

Hard

Created by

AR GARY WONG

Used 5+ times

FREE Resource

9 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one statement is not true purpose Street, Drainage & Building Act (SDBA)

An act to standardise and amend regulations related to streets, drains and buildings in a local council

An act for local council to develop, improve and repair streets, drainage and buildings for the betterment of the district

An act for local council to review, process and approve or reject development plan submissions by PSP and SP

The act specify local council to manage landscaping ie trees, plants and grass within the district.

An act related to street, drainage and building commonly use by all local councils in Malaysia

2.

MULTIPLE SELECT QUESTION

30 sec • 1 pt

Which statements is true on the purpose and function of Uniform Building Bylaws (UBBL)?

A bylaw use to standardise and manage building plan submissions for approval by PSP

A bylaw to manage and expedite the building approval process, construction and occupation of buildings

A bylaw which regulate the design aspects for architecture, structure, construction and firefighting for the safety and health of building occupants

A bylaw to provide temporary building permits in connection to building operations

A bylaw which regulate the external services serving the building ie roads, drains, sewer, electricity etc

3.

MULTIPLE SELECT QUESTION

20 sec • 1 pt

What are the following are the determining factors in fire fighting requirements for any development?

The purpose group of a building

The height of building

The total volume of the building

The fire appliance accessway of the building

The plinth area of the building

4.

MULTIPLE CHOICE QUESTION

20 sec • 1 pt

What is the criteria to determine the wet or dry riser systems?

The requirements outlined in the purpose group of a building

The total height of the building from fire appliance access

The total height to the topmost usable floor of the building from fire appliance access

The requirements listed in the tenth schedule for fire extinguishment system

5.

MULTIPLE SELECT QUESTION

20 sec • 1 pt

What are the related factors stated in the UBBL to comply which relates to occupants' health?

Room construction

Room height, width or length

Room area

Room finishes

Room daylighting ventilation

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following statements is false?

A fire fighting shaft is provided for fire fighters to access and fight fire

Smoke lobby is provided at every floor of every escape staircase to prevent smoke built-up into the staircase

The fire staircase flight width calculation design shall be based on the no of staircases available (minus one) and total no of occupants on the storey exit

The fire staircases shall exit directly out to the fire appliance accessway

Fire or escape staircases exit shall not discharge to other compartments within the buildings

7.

MULTIPLE SELECT QUESTION

20 sec • 1 pt

Which of the fire appliance accessway requirements are true?

The fire appliance access must have a minimum road width of 6m wide

The min road gradient of fire appliance access is 1 : 12

The allowable fire appliance access road max length without a turning facilities is 46m

Overhead min clearance along the fire appliance accessway shall by 4m

Fire control room shall be located close and easily accessible from the entrance

8.

MULTIPLE SELECT QUESTION

20 sec • 1 pt

The 5 principles of fire fighting are prevention, detection and communication, occupant protection, containment and extinguishment. Which of these are considered passive fire fighting?

Prevention

Detection and communication

Occupant protection

Containment

Extinguishment

9.

MULTIPLE SELECT QUESTION

30 sec • 1 pt

What are the relevant bylaws related to staircases which is true?

There are requirements for riser max height of 180mm and tread min depth 275mm

Maximum no of risers allowed per flight is 14

Railing height of staircase shall be 850mm to 900mm high

Minimum width of staircase allowed is 750mm

the staircase landing depth shall be equal or less than the width of the stair flight