Level I Questions Mass Spectrometer Testing Method

Level I Questions Mass Spectrometer Testing Method

68 Qs

quiz-placeholder

Similar activities

Science Final Review

Science Final Review

7th Grade

67 Qs

PSD Final Exam

PSD Final Exam

KG - University

65 Qs

Choir Semester Exam

Choir Semester Exam

6th - 8th Grade

66 Qs

Honors Biology Final Practice

Honors Biology Final Practice

KG - University

71 Qs

Chemistry: First Semester Final

Chemistry: First Semester Final

University

66 Qs

Voting Exam: Government

Voting Exam: Government

12th Grade

65 Qs

Chapter 17 - Quality Management Quiz

Chapter 17 - Quality Management Quiz

10th Grade - University

63 Qs

Grammar, Punctuation & Spelling Revision

Grammar, Punctuation & Spelling Revision

KG - University

64 Qs

Level I Questions Mass Spectrometer Testing Method

Level I Questions Mass Spectrometer Testing Method

Assessment

Quiz

others

Practice Problem

Hard

Created by

Sang Quang

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

68 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A vapor is best defined as:

water in a test system
a substance which, though present in the gaseous phase, exists as a liquid at room temperature
a substance in the gaseous state whose temperature is above its critical temperature
a substance in the liquid state whose temperature is below its critical temperature

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Gage pressure is:

the harmonic pressure within a gage
atmospheric pressure plus absolute pressure
the difference between absolute and atmospheric pressure
a sum of the partial pressures of air at standard temperature and pressure

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

All leak testing methods are dependent upon;

barometric pressure
gas or liquid flow
mass spectrometer analysis
mean free paths of helium flow

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A type of virtual leak caused by the slow release of absorbed or entrapped tracer gas in a helium mass spectrometer vacuum system is a:

hang-up
condenser
getter
molecular leak

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The sensitivity of a mass spectrometer leak detector system is the mass flow rate of tracer gas:

that gives a maximum measurable signal
that gives a minimum measurable signal
at standard temperature and pressure
in a leak

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

As the required sensitivity of a leak test increases, the cost of the test:

decreases
remains constant
increases
decreases exponentially

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following can be considered a major class of mass spectrometer leak testing?

static test
dynamic test
both a and b
none of the above

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?