GMJ 6189 CH - @B@ needs answers

GMJ 6189 CH - @B@ needs answers

Vocational training

57 Qs

quiz-placeholder

Similar activities

Revision 2

Revision 2

KG - University

60 Qs

Cold Water PowerPoint 5

Cold Water PowerPoint 5

KG - University

57 Qs

Revision 4

Revision 4

KG - University

60 Qs

Gas Tap Quiz

Gas Tap Quiz

Professional Development

62 Qs

Chimney/Flue Systems Quiz

Chimney/Flue Systems Quiz

Professional Development

53 Qs

PH1 cold water

PH1 cold water

KG

52 Qs

central heating 3

central heating 3

2nd Grade

60 Qs

Heating and Cooling Systems Quiz

Heating and Cooling Systems Quiz

KG - University

60 Qs

GMJ 6189 CH - @B@ needs answers

GMJ 6189 CH - @B@ needs answers

Assessment

Quiz

Construction

Vocational training

Hard

Created by

Glen Johnson

FREE Resource

57 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Which one of the following types of heating system uses the components shown in the image below?

S plan

Y plan

W plan

C plan

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What legislation describes the requirement to have separately zoned space heating areas in dwellings?

Building regulations part L

CORGI 5th edition

British standard 6700

Water regulations guide

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A controller program that measures whether a room is warm before start up is a

Positive start

Delayed start

Relay start

Manual start

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following uses a slinky to obtain its heat energy?

Air source heat pump

Solar thermal system

Wind turbine generator

Ground source heat pump

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following is most likely to ensure an even average temperature on the floor surface in an under floor heating system incorporating long pipework runs?

Asymmetrical pattern

Spider pattern

Serpentine pattern

Symmetrical pattern

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

With a mixed heat emitter and underfloor heating system, the underfloor heating temperature operates

Hotter than the heat emitters

In conjunction with the boiler interlock setting

Lower than the heat emitters

Independently of the boiler interlock setting

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a property with suspended timber floors, the recommended operating temperature of a mixing valve in an underfloor heating system is approximately

25 degrees

40 degrees

55 degrees

70 degrees

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?