Aircraft 123

Aircraft 123

1st - 5th Grade

22 Qs

quiz-placeholder

Similar activities

Pre-Test

Pre-Test

1st Grade

20 Qs

General Revision

General Revision

2nd Grade

17 Qs

112學年度上學期5年級Raz決賽

112學年度上學期5年級Raz決賽

1st - 5th Grade

20 Qs

Homophone Mix-ups Quiz

Homophone Mix-ups Quiz

4th Grade

20 Qs

Learning Beyond Quiz Grade 1 December

Learning Beyond Quiz Grade 1 December

1st Grade

20 Qs

STEM_VSC_Times City

STEM_VSC_Times City

5th Grade

20 Qs

Furniture in Room

Furniture in Room

1st - 5th Grade

17 Qs

Test 1

Test 1

1st - 5th Grade

19 Qs

Aircraft 123

Aircraft 123

Assessment

Quiz

Others

1st - 5th Grade

Easy

Created by

Lary Over

Used 2+ times

FREE Resource

22 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What does the backup generator converter do?

Changes variable voltage into 115V/400H2

Converts DC power to AC

Changes variable frequency into 115V/400H2

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which power management panel gets power from the hot battery bus?

P300 APU auxiliary panel

P10O power panel

P310 standby power panel

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which unit controls the no-breaks power transfer?

Bus power control unit (BPCU)

Backup converter

Generator control unit (GCU)

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

With AC power on the airplane, what happens when you place the standby power switch to the BAT position?

The static inverter comes on and powers the standby AC bus

A DC/standby self check starts

Nothing will happen

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On which version of the 777 will you find the P330 panel?

All versions

200/300

Freighter

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following statements is true?

The 777 line replaceable units (LRUs) and line replaceable modules (LRMs) use different databuses

The 777 line replaceable units (LRUs) and line replaceable modules (LRMs) use the same databuses

The 777 line replaceable units (LRUs) and line replaceable modules (LRMs) do not use databuses

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Pneumatic bleed air is supplied by:

APU only

2 stages of the low pressure compressor

2 stages of the high pressure compressor

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?