Electrical sockets Quiz

Electrical sockets Quiz

Vocational training

10 Qs

quiz-placeholder

Similar activities

Earthing and Bonding

Earthing and Bonding

KG - University

8 Qs

Quiz on Electrical Equipment and Plumbing Objectives

Quiz on Electrical Equipment and Plumbing Objectives

KG - University

8 Qs

303 #6 - Fault Current Ratings & Standard Circuits Quiz

303 #6 - Fault Current Ratings & Standard Circuits Quiz

KG - University

10 Qs

Electrical Theory (Electrical L1) Quiz

Electrical Theory (Electrical L1) Quiz

12th Grade

10 Qs

Electricity Safety in Carpentry

Electricity Safety in Carpentry

KG - University

10 Qs

CCTV Components and Functions Quiz

CCTV Components and Functions Quiz

11th Grade

7 Qs

Electrical Supply Quiz

Electrical Supply Quiz

12th Grade

15 Qs

Electrical Concepts Quiz

Electrical Concepts Quiz

KG - University

15 Qs

Electrical sockets Quiz

Electrical sockets Quiz

Assessment

Quiz

Construction

Vocational training

Medium

Created by

John Shermer

Used 1+ times

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum live conductor cross-sectional area for a Ring circuit using mineral insulated cables?

1.0 mm²

1.5 mm²

2.0 mm²

2.5 mm²

Answer explanation

The minimum live conductor cross-sectional area for a Ring circuit using mineral insulated cables is 1.5 mm², as specified in electrical standards to ensure safety and efficiency.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum floor area for an A2 radial circuit?

50m²

75m²

100m²

25m²

Answer explanation

The maximum floor area for an A2 radial circuit is 75m², which is specified in electrical regulations. This allows for adequate load distribution and safety in installations.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the current rating for the CCU in an A3 radial circuit?

30A

20A

25A

32A

Answer explanation

In an A3 radial circuit, the current rating for the CCU is typically 20A. This rating ensures safe operation and compliance with electrical standards, making 20A the correct choice among the options provided.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of cable is used in an A3 radial circuit?

4mm² PVC cable

2.5mm² PVC cable

3mm² PVC cable

5mm² PVC cable

Answer explanation

An A3 radial circuit typically uses 2.5mm² PVC cable, which is suitable for lighting and socket circuits. The other options, like 4mm² and 5mm², are generally used for higher load applications.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the alternative cable type mentioned for A2 radial circuits?

1.5mm² mims cable

2.5mm² mims cable

3mm² mims cable

4mm² mims cable

Answer explanation

The alternative cable type for A2 radial circuits is the 2.5mm² mims cable, which is commonly used due to its suitable current-carrying capacity and flexibility for various applications.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the alternative cable type mentioned for A3 radial circuits?

1.5mm² mims cable

2.5mm² mims cable

3mm² mims cable

4mm² mims cable

Answer explanation

The alternative cable type for A3 radial circuits is the 1.5mm² mims cable, which is suitable for lower power applications, making it the correct choice among the options provided.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which radial circuit uses a 2.5mm² PVC cable?

A1 Radial

A2 Radial

A3 Radial

A4 Radial

Answer explanation

The 2.5mm² PVC cable is typically used for lighting and power circuits. A3 Radial is the correct choice as it specifies the use of this cable size for radial circuits, making it suitable for general power distribution.