1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1.              Pendant type socket-outlets include a switch that allows termination and switching of?

    neutral and earth conductor

   neutral and earth conductor

  active and active conductors 

  active and neutral conductors

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1.              According to AS/NZS 3003, what is the maximum rated residual current permitted for RCDs used as Leakage Protection Devices (LPDs) in a body-protected area of a hospital ward?

500mA

30mA

10mA

100mA

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1.              An engine-driven generating set is used to provide an alternative supply to the main switchboard of an installation that has an MEN connection. According to AS/NZS 3000, any neutral-earth connection within the generator must be:

isolated
disconnected
bonded
grounded

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1.              Final subcircuit protection devices on a main switchboard are electrically connected:

after the main switch
in series with the main switch
downstream from the main switch
before the main switch

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where the sheath of construction wiring is the same colour as the sheath of permanent wiring, the construction wiring must be identified by attaching yellow tape with the words ‘CONSTRUCTION WIRING’ along each cable at intervals not exceeding

5m

15 m

10 m

20 m

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

It is proposed to install a socket-outlet inside a sauna room. What limitation does AS/NZS 3000 place on this proposal?

Socket-outlets can be installed anywhere in the sauna without restrictions.
Only standard household sockets are allowed in sauna rooms.
Socket-outlets must be installed directly next to the sauna heater.

Socket-outlets must not be installed inside a sauna room

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A catenary support system is to be used to run a 2.5mm² TPS cable across the backyard of a residential premises. The area is not used by vehicles. What is the minimum height specified by AS/NZS 3000 for the catenary support system above finished ground level?

2.5 meters
2.0 meters
3.0 meters
1.5 meters

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?