07. ACR-104 UNIT 22 PRACTICE TEST

07. ACR-104 UNIT 22 PRACTICE TEST

University

10 Qs

quiz-placeholder

Similar activities

Flexible Manufacturing System (FMS)

Flexible Manufacturing System (FMS)

University

15 Qs

Refrigeration Cycle 2

Refrigeration Cycle 2

University

13 Qs

03. ACR-104 UNIT 21 PRACTICE TEST

03. ACR-104 UNIT 21 PRACTICE TEST

University

10 Qs

Digital Footprint & Passwords

Digital Footprint & Passwords

4th Grade - University

15 Qs

Components of Computer System

Components of Computer System

University

10 Qs

Fundamental of Common Rail Diesel Fuel System

Fundamental of Common Rail Diesel Fuel System

University - Professional Development

15 Qs

2.10 brazing quiz

2.10 brazing quiz

University

10 Qs

DSS-QUIZ

DSS-QUIZ

University

10 Qs

07. ACR-104 UNIT 22 PRACTICE TEST

07. ACR-104 UNIT 22 PRACTICE TEST

Assessment

Quiz

Instructional Technology

University

Hard

Created by

Jansen Godley

FREE Resource

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A device that passes outside air over water to remove the system heat is a ______

cooling tower

shell-and-tube condenser

water tower

shell-and-coil condensers

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Natural draft, forced draft, and evaporative are all types of _______.

refrigerant phases

cooling towers

wastewater systems

package refrigeration systems

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Condensing temperatures can be reduced by reducing the condenser surface area.

True

False

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Check My Work

For every 1 degree rise in suction gas temperature returning to the compressor, there will be a _____ degree rise in the compressor’s discharge temperature.

1

30

5

10

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A __________ can be piped into the high-side of the system to cycle the condenser fan on and off during a low ambient condition.

thermostatic expansion valve (TXV)

pressure control

head pressure regulator (HPR)

thermostat

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On a system that uses condenser flooding to control head pressure during low ambient conditions, the receiver should be sized so that it is ___________.

100% full when it contains the entire system charge

50% full at all times, during all conditions

80% full when it contains the entire system charge

20% full when the system is operating during a low ambient condition

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Any refrigerant receiver should be able to hold all of the system’s charge and still have a 25% vapor head for safety.

True

False