Search Header Logo

36 review

Authored by Robert Hemmila

Science

University

NGSS covered

Used 12+ times

36 review
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

18 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The total heat content of infiltrated air of the same dry-bulb temperature may vary from one part of the country to another because of the difference in ____.

solar load
sensible heat
humidity
convection currents

Tags

NGSS.MS-ESS2-4

NGSS.MS-ESS2-6

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A homeowner plans to build a house out in Las Vegas, Nevada, in the middle of the desert. It would be in his/her best interest to lower the "solar load," to locate most of the windows on the ____ sides of the house.

north and east
east and west
north and south
south and west

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The solar load on a structure is the heat gain resulting from the ____.

heat from the surrounding air conducted through the materials of the structure
air infiltration
heat from the radiation from the sun
dry-bulb inside the structure

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

More than one evaporator coil circuit is used when ____.

the evaporator is located outside the conditioned area
there would be excessive refrigerant pressure drop in the coil circuit
a distributor would not be practical
a slant coil is at an angle more than 60°

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In reciprocating compressors used in air conditioning, the motor is mainly cooled by ____.

air over the shell of the assembly

discharge gas from the compressor

suction gas returning to the compressor

Both a and c.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A dirty condenser coil can lead to ____.

increased efficiency

reduced efficiency

reduced head pressure

increased subcooling

Tags

NGSS.MS-PS3-3

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

High-efficiency condensers ____.

can withstand higher pressures than standard condensers

have more surface area than standard condensers

have stainless steel coils

are located in separate cabinets

Tags

NGSS.MS-PS3-3

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?