Search Header Logo

Air Conditioning System Quiz

Authored by Rahul Koppu

Others

University

Used 1+ times

Air Conditioning System Quiz
AI

AI Actions

Add similar questions

Adjust reading levels

Convert to real-world scenario

Translate activity

More...

    Content View

    Student View

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Conditioned air is distributed to:

Cockpit, cargo bays and cabin

Cockpit, fwd and aft cabins

Cockpit, avionics bay and cabin

Cockpit, cabin and holds 1 and 2 only

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Hot air fault light illuminates on the air conditioning panel,

The hot air press. reg. valve opens and the trim air valves close.

The hot air press. reg. valve closes and the trim air valves open.

The hot air press. reg. valve closes and the trim air valves close.

The hot air press. reg. valve opens and the trim air valves open.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Does the trim air provide the warm air or the cold air to the air conditioning system?

Cold air

Warm air

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In case of zone controller primary and secondary channel failure, what temperatures are maintained by pack one and pack two?

15 deg C both

25 deg C both

20 deg C for pack one and 10 deg C for pack two

24 deg C for pack one and 15 deg C for pack two

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In normal flight in closed circuit configuration, the avionics ventilation system controls the temperature of the cooling air by:

Adding air conditioned air to the flow

Extracting air overboard

Adding avionics bay air

Passing air through a skin heat exchanger

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

To enable Ram air to the mixture unit, The Ram air switch should be used:

At any time

Only when differential pressure is less than 1 psi.

When pressure is greater than 1 psi diff.

Only after outflow valve is fully opened

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Pack controller, primary channel failure.

The secondary computer operates as a backup mode and regulation is not optimized

The secondary computer takes over (all functions as normal)

Pack is lost

Pack outlet temperature is controlled at 15 deg C

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?