08. ACR-104 UNIT 22 EOU TEST

08. ACR-104 UNIT 22 EOU TEST

University

32 Qs

quiz-placeholder

Similar activities

Bài Quiz không có tiêu đề

Bài Quiz không có tiêu đề

3rd Grade - University

27 Qs

SA1_ Què és la tecnologia?

SA1_ Què és la tecnologia?

7th Grade - University

30 Qs

Java Quiz I- B

Java Quiz I- B

University

31 Qs

UNIT 2 Chapter Test

UNIT 2 Chapter Test

University

30 Qs

Mesin-mesin Listrik I

Mesin-mesin Listrik I

University

27 Qs

Special Federal Aviation Regulation No. 27

Special Federal Aviation Regulation No. 27

12th Grade - University

27 Qs

Fundamentals of Turbochargers

Fundamentals of Turbochargers

University

27 Qs

Systems Engineering Yamette!

Systems Engineering Yamette!

University

28 Qs

08. ACR-104 UNIT 22 EOU TEST

08. ACR-104 UNIT 22 EOU TEST

Assessment

Quiz

Instructional Technology

University

Practice Problem

Medium

Created by

Jansen Godley

Used 5+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

32 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The refrigerant in a condenser in a refrigeration system ____.

absorbs heat

rejects heat

changes to a vapor

is under lower pressure than the evaporator

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The condenser in a refrigeration system ____.

desuperheats the vapor from the compressor

condenses the vapor from the compressor

subcools the liquid refrigerant before it leaves the condenser

All of the above.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A normally operating water-cooled condenser is operating with a 10°F differential between water in and water out. If scale forms on the water tubes and the entering water is 85°F, which of the following is possible?

The outlet water temperature will be lower than expected.

The system head pressure will rise.

The water regulating valve will close.

Both a and b are correct.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Mineral deposits on the water side of a water-cooled condenser act as a(n) ____.

conductor of heat

insulator

cleaning solution

They have no effect on the operation of the condenser.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a water-cooled condenser with dirty condenser tubes, the temperature difference between the refrigerant and the leaving water will be ____ when the tubes are clean.

less than

greater than

the same as

slightly lower than

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The water circuit in shell-and-coil and tube-within-a-tube coil condensers must be cleaned ____.

by removing the end caps

with a brush

chemically

by air pressure

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The shell-and-tube condenser is cleaned ____.

with a brush after removing the end caps

only with chemicals

with compressed air

with a vacuum cleaner

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?