08. ACR-104 UNIT 22 EOU TEST

08. ACR-104 UNIT 22 EOU TEST

University

32 Qs

quiz-placeholder

Similar activities

Capacitores

Capacitores

University

30 Qs

SISTEM PENERANGAN SEPEDA MOTOR

SISTEM PENERANGAN SEPEDA MOTOR

11th Grade - University

34 Qs

Ex 2º 1ª Ev TECH RevA

Ex 2º 1ª Ev TECH RevA

2nd Grade - University

32 Qs

MID INFOMATIKA KELAS 7

MID INFOMATIKA KELAS 7

7th Grade - University

30 Qs

A.S.E. MLR created by jb

A.S.E. MLR created by jb

10th Grade - University

35 Qs

Pressurization Modes

Pressurization Modes

12th Grade - University

30 Qs

WLD-112 BASIC WELDING FINAL

WLD-112 BASIC WELDING FINAL

11th Grade - University

30 Qs

Kopling

Kopling

University

30 Qs

08. ACR-104 UNIT 22 EOU TEST

08. ACR-104 UNIT 22 EOU TEST

Assessment

Quiz

Instructional Technology

University

Medium

Created by

Jansen Godley

Used 5+ times

FREE Resource

32 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The refrigerant in a condenser in a refrigeration system ____.

absorbs heat

rejects heat

changes to a vapor

is under lower pressure than the evaporator

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The condenser in a refrigeration system ____.

desuperheats the vapor from the compressor

condenses the vapor from the compressor

subcools the liquid refrigerant before it leaves the condenser

All of the above.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A normally operating water-cooled condenser is operating with a 10°F differential between water in and water out. If scale forms on the water tubes and the entering water is 85°F, which of the following is possible?

The outlet water temperature will be lower than expected.

The system head pressure will rise.

The water regulating valve will close.

Both a and b are correct.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Mineral deposits on the water side of a water-cooled condenser act as a(n) ____.

conductor of heat

insulator

cleaning solution

They have no effect on the operation of the condenser.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a water-cooled condenser with dirty condenser tubes, the temperature difference between the refrigerant and the leaving water will be ____ when the tubes are clean.

less than

greater than

the same as

slightly lower than

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The water circuit in shell-and-coil and tube-within-a-tube coil condensers must be cleaned ____.

by removing the end caps

with a brush

chemically

by air pressure

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The shell-and-tube condenser is cleaned ____.

with a brush after removing the end caps

only with chemicals

with compressed air

with a vacuum cleaner