08. ACR-104 UNIT 22 EOU TEST

08. ACR-104 UNIT 22 EOU TEST

University

32 Qs

quiz-placeholder

Similar activities

Electrónica analógica 1

Electrónica analógica 1

University

28 Qs

Module 3-4 ICT QUIZ

Module 3-4 ICT QUIZ

12th Grade - University

36 Qs

Unit 19 - Analyze software Requirements

Unit 19 - Analyze software Requirements

University

35 Qs

ISC Chap 8 2020 - CET 1423

ISC Chap 8 2020 - CET 1423

University - Professional Development

35 Qs

LIT 4E African Literature

LIT 4E African Literature

University

30 Qs

CIW IBA Lesson 1 Vocabulary

CIW IBA Lesson 1 Vocabulary

8th Grade - University

29 Qs

Intro to ICT 2 Midterm Examination (BTLED A Group 1)

Intro to ICT 2 Midterm Examination (BTLED A Group 1)

University

27 Qs

AP Cybersecurity 2.1  Physical Vulnerabilities and Attacks

AP Cybersecurity 2.1 Physical Vulnerabilities and Attacks

12th Grade - University

28 Qs

08. ACR-104 UNIT 22 EOU TEST

08. ACR-104 UNIT 22 EOU TEST

Assessment

Quiz

Instructional Technology

University

Medium

Created by

Jansen Godley

Used 5+ times

FREE Resource

32 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The refrigerant in a condenser in a refrigeration system ____.

absorbs heat

rejects heat

changes to a vapor

is under lower pressure than the evaporator

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The condenser in a refrigeration system ____.

desuperheats the vapor from the compressor

condenses the vapor from the compressor

subcools the liquid refrigerant before it leaves the condenser

All of the above.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A normally operating water-cooled condenser is operating with a 10°F differential between water in and water out. If scale forms on the water tubes and the entering water is 85°F, which of the following is possible?

The outlet water temperature will be lower than expected.

The system head pressure will rise.

The water regulating valve will close.

Both a and b are correct.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Mineral deposits on the water side of a water-cooled condenser act as a(n) ____.

conductor of heat

insulator

cleaning solution

They have no effect on the operation of the condenser.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a water-cooled condenser with dirty condenser tubes, the temperature difference between the refrigerant and the leaving water will be ____ when the tubes are clean.

less than

greater than

the same as

slightly lower than

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The water circuit in shell-and-coil and tube-within-a-tube coil condensers must be cleaned ____.

by removing the end caps

with a brush

chemically

by air pressure

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The shell-and-tube condenser is cleaned ____.

with a brush after removing the end caps

only with chemicals

with compressed air

with a vacuum cleaner

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?