FAB-101 EPA Week 5 Homework (Type III)

FAB-101 EPA Week 5 Homework (Type III)

12th Grade

15 Qs

quiz-placeholder

Similar activities

ALTIMETER GAME

ALTIMETER GAME

University

20 Qs

Exploring Pneumatic Technology

Exploring Pneumatic Technology

12th Grade - University

15 Qs

WELCOME TEST

WELCOME TEST

9th - 12th Grade

20 Qs

FAB-101 EPA Week 4 Homework (Type II)

FAB-101 EPA Week 4 Homework (Type II)

12th Grade

15 Qs

Refrigeration and air conditioning CO5

Refrigeration and air conditioning CO5

University

10 Qs

Lesson 7 Fluid Pressure Characteristics

Lesson 7 Fluid Pressure Characteristics

12th Grade - University

18 Qs

Air Conditioning System

Air Conditioning System

University

20 Qs

Energy Management Techniques for SoC

Energy Management Techniques for SoC

University

14 Qs

FAB-101 EPA Week 5 Homework (Type III)

FAB-101 EPA Week 5 Homework (Type III)

Assessment

Quiz

Engineering

12th Grade

Medium

Created by

Steven Estrada

Used 3+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the maximum test pressure for leak testing a low-pressure centrifugal chiller with nitrogen?

5 psig

10 psig

15 psig

20 psig

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How can charged low-pressure refrigeration machines be most effectively leak checked?

By adding refrigerant

By reducing pressure

By adding heat with hot water or heating blankets

By cooling the system

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What type of compressors are particularly susceptible to leaks from the shaft seal?

Open-drive type compressors

Closed-drive type compressors

Rotary compressors

Scroll compressors

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

According to ASHRAE Guideline 3, when should a system be checked for leaks?

If pressure rises from 1 mm Hg to 2.5 mm Hg

If pressure drops from 2.5 mm Hg to 1 mm Hg

If temperature increases

If refrigerant levels decrease

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What happens once the threshold leak rate has been exceeded on a system using a regulated refrigerant?

The system must be replaced

The system must be repaired

The refrigerant must be removed

The refrigerant must be increased

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

As of January 1, 2019, what is the maximum leak rate for comfort cooling?

10% of the charge per year

20% of the charge per year

30% of the charge per year

40% of the charge per year

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How long does an owner have to repair an appliance that has 50 pounds or more of refrigerant and has exceeded the threshold leak rate?

10 days

18 months

30 days

3 years

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?