1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
It is best practice to use dry nitrogen to break the vacuum when dehydrating by the triple evacuation method. However, it;
often contains moisture
requires a minimum of 10 psig
is toxic when released into the environment
requires a pressure regulator
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
When can appliances containing refrigerants be recovered to atmospheric pressure?
for major repairs such as replacing the compressor , condenser, or evaporator
the repair is followed by an evacuation of the appliance to the environment
leaks in the appliance make recovery to the prescribed level unattainable
the appliance is being disposed of and recycled
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Which of the following repairs would always be considered "major" under EPA's regulations
Replacement of an evaporator coil
Replacement of a filter-drier
Replacement of a Schrader valve core
Replacement of a condenser fan motor
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Before making a major repair, technicians must evacuate an appliance or component containing more than 200 pounds of R-410A to which of the following levels?
0 PSIG
25mm Hg absolute
10 inches of Hg vacuum
15 inches of Hg vacuum
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
How can you speed up the removal of the refrigerant charge from a system?
using a smaller recovery vessel
cooling the recovery cylinder to lower it's pressure
using a two-stage vacuum pump
heating the recovery cylinder to raise it's pressure
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
You are changing out the compressor of a system containing 40 pounds of R-404A. In addition to isolating the compressor, which of the following procedures should you follow?
simply remove the compressor and cap the ends
evacuate the isolated section of the system to atmospheric pressure, then remove the compressor
evacuate the isolated section of the system to 0 PSIG and if system pressure does not rise after a few minutes remove the compressor
evacuate the isolated section of the system to 18" Hg and if system pressure does not rise after a few minutes energize the compressor
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
How would you remove moisture from refrigerant in a system?
purge the condenser
drain the oil seperator
reduce water flow to the condenser
use a filter-drier
Access all questions and much more by creating a free account
Create resources
Host any resource
Get auto-graded reports

Continue with Google

Continue with Email

Continue with Classlink

Continue with Clever
or continue with

Microsoft
%20(1).png)
Apple
Others
Already have an account?
Similar Resources on Wayground
20 questions
IED Unit 1 Key Terms
Quiz
•
9th - 12th Grade
20 questions
Python IF statements Part 4
Quiz
•
9th - 12th Grade
20 questions
BASIC TECHNOLOGY 2
Quiz
•
8th - 11th Grade
21 questions
Missouri Drivers Guide
Quiz
•
10th Grade - Professi...
20 questions
Malware/ IOC
Quiz
•
10th Grade - Professi...
20 questions
CPA JYSS 2018 Prelims Paper 1
Quiz
•
7th Grade - Professio...
20 questions
SISTEM PELUMASAN
Quiz
•
11th Grade
20 questions
Principles of Design
Quiz
•
6th Grade - University
Popular Resources on Wayground
15 questions
Fractions on a Number Line
Quiz
•
3rd Grade
20 questions
Equivalent Fractions
Quiz
•
3rd Grade
25 questions
Multiplication Facts
Quiz
•
5th Grade
54 questions
Analyzing Line Graphs & Tables
Quiz
•
4th Grade
22 questions
fractions
Quiz
•
3rd Grade
20 questions
Main Idea and Details
Quiz
•
5th Grade
20 questions
Context Clues
Quiz
•
6th Grade
15 questions
Equivalent Fractions
Quiz
•
4th Grade