Progress check hot water

Progress check hot water

12th Grade

26 Qs

quiz-placeholder

Similar activities

Understand the requirements of drainage systems

Understand the requirements of drainage systems

12th Grade

31 Qs

knowledge check 3

knowledge check 3

12th Grade

27 Qs

System Components quiz

System Components quiz

12th Grade - University

26 Qs

Central Heating Pictures Quiz

Central Heating Pictures Quiz

12th Grade - University

23 Qs

Drainage Quiz 2

Drainage Quiz 2

12th Grade - University

24 Qs

Hot Water - PPT 4 - Instantaneous hot water heaters

Hot Water - PPT 4 - Instantaneous hot water heaters

12th Grade - University

21 Qs

PPT 11 - Testing and filling the central heating system

PPT 11 - Testing and filling the central heating system

12th Grade - University

25 Qs

Quizizz 4B

Quizizz 4B

12th Grade

25 Qs

Progress check hot water

Progress check hot water

Assessment

Quiz

Construction

12th Grade

Easy

Created by

Nigel Pawlett

Used 1+ times

FREE Resource

26 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum recommended distribution temperature of hot water supplied by a storage cylinder?

48°C

55°C

60°C

65°C

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which Building Regulation relates to the hot water delivery systems in dwellings?

Part F

Part G

Part P

Part L

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which one of the following is classed as a localised hot water system?

Under-sink single point heater

Thermal store

Combination boiler

Open vented

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The safety devices within an unvented hot water cylinder are designed to prevent the water from exceeding which of the following temperatures?

60°C

65°C

95°C

100°C

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where should a secondary return be connected within a hot water storage cylinder?

A quarter of the way down

Halfway down

Two-thirds of the way from the bottom

A quarter of the way up

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Identify the components in the unvented hot water system below.

1: Strainer; 2: Isolation valve; 3: Expansion relief valve; 4: Check valve

1: Isolation valve; 2: Strainer; 3: Check valve; 4: Expansion relief valve

1: Pressure reducing valve; 2: Isolation valve; 3: Check valve; 4: Strainer

1: Isolation valve; 2: Strainer; 3: Pressure reducing valve; 4: Check valve

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What temperature should the temperature relief valve fitted to an unvented hot water storage vessel be set to discharge at?

60°C

72°C

90°C

95°C