Refrigeration System Quiz

Refrigeration System Quiz

University

15 Qs

Refrigeration System Quiz

Refrigeration System Quiz

University

15 Qs

Vocabulary- Units 1-3-EE6

Vocabulary- Units 1-3-EE6

University

10 Qs

2A: Illnesses and Injuries

2A: Illnesses and Injuries

University

20 Qs

Refrigeration System Quiz

Refrigeration System Quiz

Assessment

Quiz

English

University

Easy

Created by

Laura McHugh

Used 2+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A refrigeration system has a low suction pressure and low head pressure. What is the most likely cause?

Overcharged refrigerant

Compressor short-cycling

Low refrigerant charge or restriction

TXV stuck open

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary function of a high-side float metering device?

To maintain a constant superheat in the evaporator

To regulate refrigerant flow based on condenser liquid level

To increase suction pressure

To prevent compressor overheating

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is the best method for checking if a refrigeration system is properly charged?

Checking suction pressure only

Checking head pressure only

Measuring superheat and subcooling

Verifying sight glass clarity

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What will happen if a compressor’s suction valve is damaged or leaking?

High head pressure and low suction pressure

High suction pressure and low head pressure

Frost buildup on the suction line

High amperage draw by the compressor

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When troubleshooting an electrically controlled refrigeration system, the technician finds 24V at the thermostat but the compressor does not start. What should be checked next?

The refrigerant charge

The high-pressure switch

The metering device

The discharge pressure

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What could cause excessive compressor discharge temperature?

Overcharging the system

Excessive liquid in the suction line

Low refrigerant charge or high compression ratio

TXV stuck open

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of a solenoid valve in a refrigeration system?

To control refrigerant flow during system shutdown

To regulate compressor speed

To increase refrigerant flow in low ambient conditions

To maintain constant head pressure