Chapter 4: Calibration Procedures & Documentation

Chapter 4: Calibration Procedures & Documentation

Vocational training

21 Qs

quiz-placeholder

Similar activities

CARPENTRY LEVEL ONE MODULE 27103-13 EXAM

CARPENTRY LEVEL ONE MODULE 27103-13 EXAM

9th Grade

19 Qs

garys 05

garys 05

Professional Development

26 Qs

Week 1

Week 1

KG - University

20 Qs

Week 9 Production Review Quiz

Week 9 Production Review Quiz

9th - 12th Grade

18 Qs

Woodworking Joints

Woodworking Joints

10th Grade

18 Qs

Carpentry EOPA Part 3

Carpentry EOPA Part 3

9th - 12th Grade

19 Qs

202 Outcome 2

202 Outcome 2

KG - University

20 Qs

EVALUASI PELATIHAN DUMP TRUCK

EVALUASI PELATIHAN DUMP TRUCK

Professional Development

25 Qs

Chapter 4: Calibration Procedures & Documentation

Chapter 4: Calibration Procedures & Documentation

Assessment

Quiz

Construction

Vocational training

Medium

Created by

Sarah Strahan

Used 1+ times

FREE Resource

21 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt


The industry standard output for a transmitter is   ?  .

0-10 VDC

0-10 VDC

1-5 VDC

4-20 mADC

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Proper instrument calibration is essential for a process to   ?  .

I. Increase energy consumption
II. Maintain regulatory compliance
III. Operate efficiently
IV. Prevent hazardous material release to atmosphere
V. Produce products of consistent quality

I. and III.

II., III., and IV.

I., II., III., and V.

II., III., IV., and V.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The instrument calibration procedure is based on   ?   a known accurate signal with a signal of   ?   accuracy.

comparing / unknown

measuring / proper

recording / high

varying / moderate

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The mathematical difference between the upper range value and lower range value of an instrument is defined as   ?  .

accuracy

gain

range

span

5.

FILL IN THE BLANK QUESTION

1 min • 1 pt

Determine the span of an instrument with a lower range value (LRV) of 38 psi and an upper range value (URV) of 209 psi. (Round the FINAL answer to the nearest whole number.)

6.

FILL IN THE BLANK QUESTION

1 min • 1 pt

Determine the span of an instrument with a lower range value (LRV) of 32 "H2O and an upper range value (URV) of 136 "H2O. (Round the FINAL answer to the nearest whole number.)

7.

FILL IN THE BLANK QUESTION

1 min • 1 pt

Determine the accuracy of an instrument with a maximum deviation of 0.2 mADC and an output span of 16 mADC. (Round the FINAL answer to two decimal places.)