Hot Water - PPT 5 - Showers

Hot Water - PPT 5 - Showers

12th Grade

30 Qs

quiz-placeholder

Similar activities

Hot Water - PPT 8 - Install hot water systems and components

Hot Water - PPT 8 - Install hot water systems and components

12th Grade

34 Qs

PPT 8,9,10 DRAINAGE QUIZ

PPT 8,9,10 DRAINAGE QUIZ

12th Grade - University

32 Qs

Plumbing Techniques and Regulations Quiz

Plumbing Techniques and Regulations Quiz

12th Grade

33 Qs

PPT 3 - Central heating systems installed in domestic dwellings

PPT 3 - Central heating systems installed in domestic dwellings

12th Grade - University

25 Qs

Hot Water - PPT 3 - Pipework and Circulation

Hot Water - PPT 3 - Pipework and Circulation

12th Grade

32 Qs

PPT 6 - Installation and backflow prevention

PPT 6 - Installation and backflow prevention

12th Grade

27 Qs

PPT 2 - Central heating system principles

PPT 2 - Central heating system principles

12th Grade - University

28 Qs

Hot Water - PPT 5 - Showers

Hot Water - PPT 5 - Showers

Assessment

Quiz

Construction

12th Grade

Hard

Created by

Adam Dreifuss

Used 1+ times

FREE Resource

30 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is a type of shower mixer valve?

Gravity mixer

Pressure valve

Thermal mixer

Rotary valve

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is one classification of shower mixer valves?

Mains-fed/boosted mixer

Hydraulic mixer

Solar mixer

Pneumatic mixer

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of having the cold water feed to the cylinder higher than the cold for the shower in a cistern-fed/gravity mixer system?

To ensure the cold water runs out first

To ensure the hot water runs out first

To balance the water pressure

To reduce water temperature

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum head required for the shower mixer valve in a cistern-fed/gravity mixer system?

0.5m

1m

1.5m

2m

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended pipe size before reducing to 15mm in a cistern-fed/gravity mixer system?

10mm

15mm

22mm

30mm

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is required for a cistern-fed/gravity mixer to function properly?

Unequal pressure

Equal pressure

High pressure

No pressure

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

From where are both the hot and cold water fed in a cistern-fed/gravity mixer?

Directly from the mains

From the CWSC

From a separate tank

From a boiler

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?