1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The primary function of the AC normal generation is to supply electrical power to the users on ground or in flight through the sources that follow: (level 3)
Ground Power Unit(s) (GPU(s)), Auto Transformer Units (ATUs), APU generator, Variable Frequency Generators (VFGs),
Ground Power Unit(s) (GPU(s)), Auto Transformer Units (ATUs), APU generator, Integrated Driven Generators (IDGs),
Ground Power Unit(s) (GPU(s)), APU generator, Variable Frequency Generators (VFGs),

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In normal configuration, the APU generator supply the aircraft electrical network: (level 2)
Three phases, 115VAC, 400Hz constant frequency.
Three phases, 230VAC, frequency range from 360Hz and 800Hz.
Three phases, 230VAC, 400Hz constant frequency.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The SGCU (Starter Generator Control Unit) manages: (level 2)
The regulation and protection for the Generate mode of the APU SG (Auxiliary Power Unit Starter Generator),
The regulation and protection for the Generate mode of the air starter and generator,
Both answer are correct

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What are functions of SGCU (Starter Generator Control Unit)? (level 2)
It supplies power to Electrical network.
It manages the regulation and protection APU Starter Generator in Generate mode.
It sends command to ECB to control APU.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Maximum continuous power of VFG (Variable Frequency Generator) is: (level 3)
90 kVA,
100 kVA,
150 kVA.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Properties of the VFGs (Variable Frequency Generators) are: (level 3)
Three phases, 230VAC, 400Hz constant frequency.
Three phases, 230VAC, frequency range from 360Hz and 800Hz depending on the N3 rotor speed.
Three phases, 115VAC, frequency range from 360Hz and 800Hz depending on the N3 rotor speed.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On ELEC panel the DRIVE P/BSW controls: (level 2)
The thermal disconnection of the VFG (Variable Frequency Generator).
The exciter generator cut off.
The mechanical disconnection of the VFG (Variable Frequency Generator).

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?