18 Edition Part 5 (a)

18 Edition Part 5 (a)

12th Grade

20 Qs

quiz-placeholder

Similar activities

Timber Repairs final quiz

Timber Repairs final quiz

12th Grade - University

17 Qs

202 Revision Extra questions

202 Revision Extra questions

12th Grade

20 Qs

Safety in the Workshop

Safety in the Workshop

9th Grade - University

15 Qs

ALINEA ND ZOE TRIVIA

ALINEA ND ZOE TRIVIA

12th Grade - University

21 Qs

3D ID Stewart Residence

3D ID Stewart Residence

9th - 12th Grade

24 Qs

Timber Stud Partitions Quiz

Timber Stud Partitions Quiz

12th Grade

15 Qs

Plumbing L1 Baseline assessment

Plumbing L1 Baseline assessment

12th Grade

20 Qs

Maintenance 210

Maintenance 210

12th Grade - University

16 Qs

18 Edition Part 5 (a)

18 Edition Part 5 (a)

Assessment

Quiz

Construction

12th Grade

Medium

Created by

Ross Howell

Used 3+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which one of the following devices would not be suitable for use as a circuit isolator? Mark one answer

A. A contactor

B. A device with semiconductors

C. A fuse

D. An RCD

Answer explanation

Amendment 2 (Brown Book) Reference: Page 184, table 537.4

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Wiring systems shall be selected and erected so as to be suitable for?

The highest and lowest local ambient temperature

The maximum ambient temperature

The maximum and minimum conductor temperature

The maximum conductor temperature

Answer explanation

Amendment 2 (Brown Book) Reference: Page 141, section 522.1.1

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Type 1 SPD's (Surge Protection Devices) are often referred to as?

Earth bonding SPD's

Equipotential bonding SPD's

Exposed conductive SPD's

Extraneous conductive SPD's

Answer explanation

Amendment 2 (Brown Book) Reference: Page 164, section 534.4.1.1

4.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

An item of switchgear is installed behind a fixed panel thus making the operation of the switchgear impossible for the operator to observe. In such situations a suitable indicator must be fixed in a position where the operator can see the effect of the operation, the indicator must comply with?

BS EN 12954

BS EN 3535

BS EN 4444 or BS EN 6346

BS EN 60073 and BS EN 60447

Answer explanation

Amendment 2 (Brown Book) Reference: Page 132, section 514.1.1

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

All outdoor lighting installations need to be carefully selected and erected, but which type of lighting is excluded from BS 7671? Mark one answer

Advertising signs

Festoon lighting that is temporary

Phone kiosks

Road lighting

Answer explanation

Amendment 2 (Brown Book) Reference: Page 220, section 559.1 (iii)

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What is the maximum operating temperature for thermosetting cables?

105°C

70°C

80°C

90°C

Answer explanation

Amendment 2 (Brown Book) Reference: Page 145, table 52.1

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Media Image

What type of circuits do the images below represent? Mark one answer

Auxiliary circuits

Generator control circuits

IT systems

Safety services circuits

Answer explanation

Amendment 2 (Brown Book) Reference: Page 215, Figure 55.2 and section 557 in, page 216

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?