18 Edition Part 5 (a)

18 Edition Part 5 (a)

12th Grade

20 Qs

quiz-placeholder

Similar activities

Kuiz Kerja Konkrit

Kuiz Kerja Konkrit

11th Grade - University

20 Qs

Cuestionario sin título

Cuestionario sin título

12th Grade - University

15 Qs

Belt and Disc Sander - Safety procedure Quiz

Belt and Disc Sander - Safety procedure Quiz

7th Grade - University

20 Qs

Module 9

Module 9

9th Grade - University

15 Qs

Construction Quiz End of Unit

Construction Quiz End of Unit

12th Grade

20 Qs

Hammers & Pry bars

Hammers & Pry bars

12th Grade

18 Qs

Accidents and emergency reporting (ppt1) (Level 1, unit 201)

Accidents and emergency reporting (ppt1) (Level 1, unit 201)

12th Grade

15 Qs

Cordless Drill Identification of Components #2

Cordless Drill Identification of Components #2

11th Grade - University

15 Qs

18 Edition Part 5 (a)

18 Edition Part 5 (a)

Assessment

Quiz

Construction

12th Grade

Practice Problem

Medium

Created by

Ross Howell

Used 3+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Which one of the following devices would not be suitable for use as a circuit isolator? Mark one answer

A. A contactor

B. A device with semiconductors

C. A fuse

D. An RCD

Answer explanation

Amendment 2 (Brown Book) Reference: Page 184, table 537.4

2.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Wiring systems shall be selected and erected so as to be suitable for?

The highest and lowest local ambient temperature

The maximum ambient temperature

The maximum and minimum conductor temperature

The maximum conductor temperature

Answer explanation

Amendment 2 (Brown Book) Reference: Page 141, section 522.1.1

3.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Type 1 SPD's (Surge Protection Devices) are often referred to as?

Earth bonding SPD's

Equipotential bonding SPD's

Exposed conductive SPD's

Extraneous conductive SPD's

Answer explanation

Amendment 2 (Brown Book) Reference: Page 164, section 534.4.1.1

4.

MULTIPLE SELECT QUESTION

2 mins • 1 pt

An item of switchgear is installed behind a fixed panel thus making the operation of the switchgear impossible for the operator to observe. In such situations a suitable indicator must be fixed in a position where the operator can see the effect of the operation, the indicator must comply with?

BS EN 12954

BS EN 3535

BS EN 4444 or BS EN 6346

BS EN 60073 and BS EN 60447

Answer explanation

Amendment 2 (Brown Book) Reference: Page 132, section 514.1.1

5.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

All outdoor lighting installations need to be carefully selected and erected, but which type of lighting is excluded from BS 7671? Mark one answer

Advertising signs

Festoon lighting that is temporary

Phone kiosks

Road lighting

Answer explanation

Amendment 2 (Brown Book) Reference: Page 220, section 559.1 (iii)

6.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

What is the maximum operating temperature for thermosetting cables?

105°C

70°C

80°C

90°C

Answer explanation

Amendment 2 (Brown Book) Reference: Page 145, table 52.1

7.

MULTIPLE CHOICE QUESTION

2 mins • 1 pt

Media Image

What type of circuits do the images below represent? Mark one answer

Auxiliary circuits

Generator control circuits

IT systems

Safety services circuits

Answer explanation

Amendment 2 (Brown Book) Reference: Page 215, Figure 55.2 and section 557 in, page 216

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?