35 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where are the statutory requirements for the installation of drainage systems?

BS 6700

BS EN 12056

Building regulations

WRAS

Answer explanation

The statutory requirements for drainage system installation are detailed in BS EN 12056, which provides guidelines for the design and installation of gravity drainage systems in buildings.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

Identify this type of stack system.

Primary ventilated stack

Secondary ventilated stack

Ventilated discharge branch stack

Stub stack

Answer explanation

A secondary ventilated stack is designed to improve drainage and reduce the risk of siphoning by allowing air to enter the system. This distinguishes it from primary ventilated stacks, making it the correct choice.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If a discharge branch has a gradient of 18mm per metre and the branch is 3 metres in length, what will the vertical drop distance be?

54mm

18mm

36mm

72mm

Answer explanation

To find the vertical drop, multiply the gradient (18mm/m) by the length of the branch (3m). So, 18mm/m * 3m = 54mm. Therefore, the vertical drop distance is 54mm.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What is the purpose of the component shown below, when installed at the base of the stack?

To prevent evaporation

To prevent backflow

To prevent expansion

To prevent compression

Answer explanation

The component at the base of the stack is a LONG RADIUS BEND OR SWEPT BEND this is designed to prevent compression over the knuckle bend or 90 degree sharp bend which can cause compression

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The maximum recommended length of a discharge pipe from a bath connected to a primary ventilated stack is:

3 metres

4 metres

5 metres

6 metres

Answer explanation

The maximum recommended length of a discharge pipe from a bath connected to a primary ventilated stack is 3 metres. This ensures proper drainage and ventilation, preventing potential issues with backflow or blockages.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the recommended termination, as per building regulations, for a soil stack inside a building?

Open ended

Cowl

Domical cage

Air admittance valve

Answer explanation

The recommended termination for a soil stack inside a building is an air admittance valve. This device allows air to enter the drainage system, preventing vacuum formation and ensuring proper drainage without the need for external venting.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the minimum sized waste that is allowed to be fitted to a wash basin?

32mm

40mm

50mm

100mm

Answer explanation

The minimum size of waste that can be fitted to a wash basin is 32mm. This size is standard for ensuring proper drainage and compatibility with typical plumbing systems.

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?

Similar Resources on Wayground