Where are the statutory requirements for the installation of drainage systems?
sanitation ph23 prt1

Quiz
•
Construction
•
2nd - 5th Grade
•
Hard

romin gouran
Used 6+ times
FREE Resource
35 questions
Show all answers
1.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
BS 6700
BS EN 12056
Building regulations
WRAS
Answer explanation
The statutory requirements for drainage system installation are detailed in BS EN 12056, which provides guidelines for the design and installation of gravity drainage systems in buildings.
2.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
Identify this type of stack system.
Primary ventilated stack
Secondary ventilated stack
Ventilated discharge branch stack
Stub stack
Answer explanation
A secondary ventilated stack is designed to improve drainage and reduce the risk of siphoning by allowing air to enter the system. This distinguishes it from primary ventilated stacks, making it the correct choice.
3.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
If a discharge branch has a gradient of 18mm per metre and the branch is 3 metres in length, what will the vertical drop distance be?
54mm
18mm
36mm
72mm
Answer explanation
To find the vertical drop, multiply the gradient (18mm/m) by the length of the branch (3m). So, 18mm/m * 3m = 54mm. Therefore, the vertical drop distance is 54mm.
4.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the purpose of the component shown below, when installed at the base of the stack?
To prevent evaporation
To prevent backflow
To prevent expansion
To prevent compression
Answer explanation
The component at the base of the stack is a LONG RADIUS BEND OR SWEPT BEND this is designed to prevent compression over the knuckle bend or 90 degree sharp bend which can cause compression
5.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
The maximum recommended length of a discharge pipe from a bath connected to a primary ventilated stack is:
3 metres
4 metres
5 metres
6 metres
Answer explanation
The maximum recommended length of a discharge pipe from a bath connected to a primary ventilated stack is 3 metres. This ensures proper drainage and ventilation, preventing potential issues with backflow or blockages.
6.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the recommended termination, as per building regulations, for a soil stack inside a building?
Open ended
Cowl
Domical cage
Air admittance valve
Answer explanation
The recommended termination for a soil stack inside a building is an air admittance valve. This device allows air to enter the drainage system, preventing vacuum formation and ensuring proper drainage without the need for external venting.
7.
MULTIPLE CHOICE QUESTION
30 sec • 1 pt
What is the minimum sized waste that is allowed to be fitted to a wash basin?
32mm
40mm
50mm
100mm
Answer explanation
The minimum size of waste that can be fitted to a wash basin is 32mm. This size is standard for ensuring proper drainage and compatibility with typical plumbing systems.
Create a free account and access millions of resources
Similar Resources on Quizizz
Popular Resources on Quizizz
15 questions
Multiplication Facts

Quiz
•
4th Grade
20 questions
Math Review - Grade 6

Quiz
•
6th Grade
20 questions
math review

Quiz
•
4th Grade
5 questions
capitalization in sentences

Quiz
•
5th - 8th Grade
10 questions
Juneteenth History and Significance

Interactive video
•
5th - 8th Grade
15 questions
Adding and Subtracting Fractions

Quiz
•
5th Grade
10 questions
R2H Day One Internship Expectation Review Guidelines

Quiz
•
Professional Development
12 questions
Dividing Fractions

Quiz
•
6th Grade
Discover more resources for Construction
15 questions
Multiplication Facts

Quiz
•
4th Grade
20 questions
math review

Quiz
•
4th Grade
5 questions
capitalization in sentences

Quiz
•
5th - 8th Grade
10 questions
Juneteenth History and Significance

Interactive video
•
5th - 8th Grade
15 questions
Adding and Subtracting Fractions

Quiz
•
5th Grade
18 questions
Main Idea & Supporting Details

Quiz
•
5th Grade
5 questions
Basement Basketball

Quiz
•
3rd Grade
20 questions
Parts of Speech

Quiz
•
3rd - 6th Grade