1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following can be directly connected to a drainage system?

a) A relief vent from a water supply system

b) A sump pump approved by the Administrative Authority

c) A waste pipe carrying discharges under pressure

d) None of the above

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

How can appliances with pumps or drainage outlets discharge waste?



a) By connecting directly to a sewer line

b) By using indirect waste pipes into an approved open receptor

c) By discharging onto the ground

d) By connecting to a drinking fountain drain

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Under what condition may clean running water used as a cooling medium discharge into a drainage system?



a) Only when directly connected

b) If approved by the Department having jurisdiction

c) Only if it discharges onto the ground

d) If connected to a closed-loop cooling system

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What must be done to chemical or industrial liquid waste before discharging into the drainage system?



a) It must be neutralized or pretreated

b) It must be diluted with clean water

c) It must be mixed with regular sewage

d) It can be discharged as-is

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary purpose of vent pipes in a plumbing system?

a) To provide water pressure

b) To prevent siphonage and back-pressure in traps

c) To store excess water

d) To filter water before it reaches the sewer

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When may vent piping be omitted on an interceptor?

a) If the interceptor acts as a primary settling tank and discharges into a secondary interceptor

b) If the plumbing system has no traps

c) If the fixtures are used less than once a day

d) If the building has a high water table

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following materials CANNOT be used underground for vent pipes?



a) Cast iron

b) PVC

c) Galvanized steel

d) Copper

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?