Type 3 Quiz

Type 3 Quiz

Professional Development

20 Qs

quiz-placeholder

Similar activities

Neurotransmitter

Neurotransmitter

University - Professional Development

15 Qs

UTAR Industrial Session

UTAR Industrial Session

University - Professional Development

15 Qs

Quality quiz

Quality quiz

Professional Development

20 Qs

GE102 - Midterm Quiz

GE102 - Midterm Quiz

Professional Development

16 Qs

Labor Relations and Negotations 1

Labor Relations and Negotations 1

University - Professional Development

15 Qs

MBIG agm quizizz

MBIG agm quizizz

Professional Development

16 Qs

Piggy quiz

Piggy quiz

KG - Professional Development

17 Qs

General Knowledge (hard)

General Knowledge (hard)

KG - Professional Development

20 Qs

Type 3 Quiz

Type 3 Quiz

Assessment

Quiz

Other

Professional Development

Practice Problem

Easy

Created by

Wayground Content

Used 2+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

The purpose of a hydrostatic tube test is to:

determine if a tube has refrigerant in it

determine if a tube is leaking

determine if the pressure inside of the tube is less than required

none of the above

2.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A chiller containing 150 pounds of HCFC refrigerant is leaking above the leak rate threshold.  The repair must be completed within ___days unless granted additional time.

repair within 60 days

repair within 35 days

repair within 30 days

not applicable, repair whenever possible

3.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

In order to determine a chillers normal charge for leak rate calculations the best method would be to:

estimate 20lb per ton

estimate 36 lb.per ton

use the charge stated on the equipment nameplate

base charge on manifold pressure readings

4.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

Under Standard 34 R-123 falls under group _________.

Select one:

A1

A2

B1

B2

5.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

A technician servicing low- pressure appliances must be certified under

Type III cert. Of section 608

Type II cert. Of section 608

Type I Of section 608

All of the above

6.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

When recharging a low-pressure system, you should allow enough ____________ to enter the system until the refrigerant saturation temperature increases to _______degrees before introducing liquid refrigerant.

vapor / 32

vapor / 36

liquid / 32

liquid / 36

7.

MULTIPLE CHOICE QUESTION

30 sec • 5 pts

During a chiller refrigerant recovery process, you should:

circulate water through the chiller to prevent water from freezing

circulate oil through the chiller to prevent water from freezing

circulate glycol to prevent the chiller water from freezing

either a or b

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?