EPA 608 Review -- TYPE 3 (English)

EPA 608 Review -- TYPE 3 (English)

12th Grade

100 Qs

quiz-placeholder

Similar activities

EPA Section 608 Preparatory Manual Review 1

EPA Section 608 Preparatory Manual Review 1

12th Grade

100 Qs

6035 Drainage Revision 2

6035 Drainage Revision 2

12th Grade

96 Qs

EPA 608 Review -- TYPE 3 (English)

EPA 608 Review -- TYPE 3 (English)

Assessment

Quiz

Construction

12th Grade

Hard

Created by

Skillpoint Alliance

Used 2+ times

FREE Resource

100 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the definition of a low-pressure appliance according to the EPA certification exam?

An appliance using a refrigerant with a liquid phase saturation pressure below 45 psia at 104 °F

An appliance using a refrigerant with a liquid phase saturation pressure above 45 psia at 104 °F

An appliance using a refrigerant with a liquid phase saturation pressure below 30 psia at 104 °F

An appliance using a refrigerant with a liquid phase saturation pressure above 30 psia at 104 °F

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following refrigerants is NOT considered low-pressure?

R-11

R-123

R-22

R-113

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is required to work on chiller systems that do not use low-pressure refrigerants?

Type I certification

Type II certification

Type III certification

No certification

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why are water lines preferred over air ducts in larger buildings for chiller systems?

Water lines are more expensive to install

Water lines are smaller and less expensive to install

Air ducts provide better cooling

Air ducts are easier to maintain

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is one method by which a chiller rejects heat to the exterior ambient air?

Direct air cooling

Water-to-air chiller

Air-to-water chiller

Direct water cooling

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the primary advantage of using a water-to-water chiller system?

Lower initial cost

Simplicity of design

Use of water in the cooling tower to lower heat rejection temperature

Higher maintenance costs

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which refrigerants are currently used in most commercial water-to-water chiller systems?

R-11

R-123

R-22

R-134a

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?