Sample Questions - Inspection and Test - Paper 2

Sample Questions - Inspection and Test - Paper 2

2nd Grade

26 Qs

quiz-placeholder

Similar activities

Microsoft Server Admin 98-365 Part 3

Microsoft Server Admin 98-365 Part 3

KG - Professional Development

22 Qs

QUIZ 3 : TOPIC 9 [ACCOUNTING FOR NON CURRENT ASSETS]

QUIZ 3 : TOPIC 9 [ACCOUNTING FOR NON CURRENT ASSETS]

1st Grade - University

25 Qs

BAB 2.3 REKA BENTUK ELEKTRIK

BAB 2.3 REKA BENTUK ELEKTRIK

1st - 12th Grade

30 Qs

Γ-Δ (1)

Γ-Δ (1)

2nd Grade

30 Qs

Final exam C3

Final exam C3

1st - 5th Grade

21 Qs

Électricité élémentaire

Électricité élémentaire

1st - 8th Grade

26 Qs

Latihan alam maya ( ・ω・)☞

Latihan alam maya ( ・ω・)☞

1st - 5th Grade

23 Qs

Aπό ποια φωνή αρχίζει η λέξη:

Aπό ποια φωνή αρχίζει η λέξη:

1st - 4th Grade

25 Qs

Sample Questions - Inspection and Test - Paper 2

Sample Questions - Inspection and Test - Paper 2

Assessment

Quiz

Education

2nd Grade

Medium

Created by

James Jones

Used 1+ times

FREE Resource

26 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

On completion of a new installation, the interval before the first periodic inspection would be decided by the:

installer.

installation designer.

client.

inspection and testing engineer.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Any addition to an existing installation should:

have a similar wiring system to that used in the existing installation.

be inspected and tested separate from the existing installation.

not impair the safety of the existing installation.

have its own energy meter separate from that of the existing installation.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following duties is ‘not’ the responsibility of the inspector?

to carry out maintenance and repairs on the installation.

to compare the test results with the design criteria.

to advise on remedial works.

to recommend the immediate isolation of defective parts.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Inspection of a fully enclosed domestic consumer unit would not need verification for:

identification of conductors.

rating and type of protective devices.

insulation resistance between live conductors and earth

correct connection of single-pole devices.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When inspecting for adequate ‘basic protection’ (protection against electric shock or direct contact) which of the following does not require inspection. Presence and condition of:

insulation.

enclosures.

barriers.

cpc’s.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The measured value of loop impedance for a circuit is 2.4Ω. If the temperature at the time of the test was 20°C and the cable is 70°C (factor 1.2) what is the corrected value. Ze = 0.4Ω:

2.88 Ω.

2.8 Ω.

2.4 Ω.

2.0 Ω.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Put the following tests in the correct sequence: 1- Continuity of CPC 2- polarity 3- ring circuit continuity 4- prospective fault current:

1.3.2.4.

2.4.1.3.

1.4.3.2.

4.1.2.3.