ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION MARCH 2016

ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION MARCH 2016

University

27 Qs

quiz-placeholder

Similar activities

Techsaavy Codeathon 2k25 Round 1

Techsaavy Codeathon 2k25 Round 1

University

25 Qs

Exploring the 8086 Microprocessor

Exploring the 8086 Microprocessor

University

25 Qs

DSP-1

DSP-1

University

25 Qs

Desperdicios en Productividad

Desperdicios en Productividad

University

22 Qs

thanhcterbodoi

thanhcterbodoi

University

22 Qs

Preguntas sobre MRP y ERP

Preguntas sobre MRP y ERP

University

23 Qs

FUNDAMENTOS DE PYTHON 2DO PARCIAL

FUNDAMENTOS DE PYTHON 2DO PARCIAL

University

23 Qs

II ECE_PCB Design Quiz

II ECE_PCB Design Quiz

University

25 Qs

 ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION MARCH 2016

ELECTRICAL ENGINEERS PRE-BOARD EXAMINATION MARCH 2016

Assessment

Quiz

Engineering

University

Practice Problem

Easy

Created by

John Anthony Torres

Used 4+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

27 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following is not a full-duplex?

Radar

Telephone

Tolemetry

Local Area Network

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a circuit breaker, the time duration from the instant of the fault extinction of arc is known as

Operating time

total clearing time

Lag time

lead time

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

For an RL circuit, the power factor cannot be less than ______ or greater than

0,1

1,0

0, -1

-1, 0

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

is the overall energy program formulated and updated yearly by the DOE, submitted to the congress pursuant to RA 7638.

Philippine Energization Program

Philippine Energy Plant

Philippine Electrification Program

Philippine Electrification Plan

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The lighting load for a dwelling expressed in terms of a unit load in volt ampere per square meter must be at least

24

12

16

2

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The capacitors of power factor correction are rated in terms of

KV

KW

KVA

KVAR

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In a balanced three phase wye connected circuit, the ine voltage are equal

To the line current

To the phase voltage

and so are the line currents

but the line currents are unequal

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?